Radar sensor for continuous level
measurement of bulk solids
VEGAPULS 69
HART and accumulator pack
Document ID: 47254

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEGAPULS 69 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vega VEGAPULS 69

  • Page 1: Quick Setup Guide

    Quick setup guide Radar sensor for continuous level measurement of bulk solids VEGAPULS 69 HART and accumulator pack Document ID: 47254...
  • Page 2: Table Of Contents

    Operating Instructions Manual as well as the Safety Manual that comes with instruments with SIL qualification. These manuals are available in the download area of "www.vega.com". Operating instructions VEGAPULS 69 - HART and power pack: Document-ID 47248 Editing status of the quick setup guide: 2017-08-10 VEGAPULS 69 • HART and accumulator pack...
  • Page 3: For Your Safety

    During work on and with the device the required personal protective equipment must always be worn. Appropriate use The VEGAPULS 69 is a sensor for continuous level measurement. Due to the integrated accumulator the instrument is particularly suitable as a portable measuring system or test sensor for special applications.
  • Page 4: Eu Conformity

    The instrument must be stationary mounted and the antenna directed vertically downward • The instrument may only be used outside closed vessels in the version with G1½ or 1½ NPT thread with integrated horn antenna. VEGAPULS 69 • HART and accumulator pack...
  • Page 5: Environmental Instructions

    That is why we have introduced an environment management system with the goal of continuously improving company environmental pro- tection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: • Chapter "Packaging, transport and storage" • Chapter "Disposal" VEGAPULS 69 • HART and accumulator pack...
  • Page 6: Product Description

    Alternatively, you can access the data via your smartphone: • Download the smartphone app "VEGA Tools" from the "Apple App Store" or the "Google Play Store" • Scan the Data Matrix code on the type label of the instrument or •...
  • Page 7: Mounting

    – Angle of inclination in two steps 0° and 90° – Angle of inclination 90°, infinitely variable Mounting instructions Polarisation Radar sensors for level measurement emit electromagnetic waves. The polarization is the direction of the electrical component of these waves. The polarization direction is marked by a nose on the housing, see following drawing: Fig. 3: Position of the polarisation Nose for marking the direction of polarisation VEGAPULS 69 • HART and accumulator pack...
  • Page 8 If you cannot maintain this distance, you should carry out a false signal suppression during setup. This applies particularly if buildup on the vessel wall is expected. In such cases, we recommend repeating the false signal suppression at a later date with existing buildup. VEGAPULS 69 • HART and accumulator pack...
  • Page 9: Connecting To Power Supply

    (accumulator life time) After pressing the key or changing the mode the yellow LED shows the accumulator status for approximately 10 s as follows: • LED lights = accumulator is full • LED flashes = accumulator should be charged VEGAPULS 69 • HART and accumulator pack...
  • Page 10 4 Connecting to power supply • LED off = accumulator is empty VEGAPULS 69 • HART and accumulator pack...
  • Page 11: Set Up With The Display And Adjustment Module

    To quickly and easily adapt the sensor to the application, select the menu item "Quick setup" in the start graphic on the display and adjustment module. Carry out the following steps with the [->] key in the below sequence. VEGAPULS 69 • HART and accumulator pack...
  • Page 12 In this menu item you enter the height of the vessel and hence the active measuring range. 5. Max. adjustment In this menu item you carry out the max. adjustment. Enter the measuring distance for 100 % filling. 6. Min. adjustment In this menu item you carry out the min. adjustment. Enter the measuring distance for 0 % filling. VEGAPULS 69 • HART and accumulator pack...
  • Page 13: Parameter Adjustment - Extended Adjustment

    To perform the adjustment, enter the distance with full and empty ves- sel, see the following example: VEGAPULS 69 • HART and accumulator pack...
  • Page 14 With the adjustment software PACTware and the PC, the stored echo curves can be displayed with high resolution and used to recognize signal changes over time. In addition, the echo curve saved during setup can also be displayed in the echo curve window and compared with the current echo curve. VEGAPULS 69 • HART and accumulator pack...
  • Page 15 Check the distance to the product surface, because if an incorrect (too large) value is entered, the existing level will be saved as a false signal. The level would then no longer be detectable in this area. VEGAPULS 69 • HART and accumulator pack...
  • Page 16: Menu Overview

    Current output - Output characteristics Mode 4 … 20 mA Reaction when malfunctions occur ≤ 3.6 mA Current output - 3.8 mA Min./Max. 20.5 mA Lock adjustment Released Display Menu item Default setting Menu language Order-specific VEGAPULS 69 • HART and accumulator pack...
  • Page 17 Lin. percent - Level put 2 able Current output - Adjustment 0 … 100 % correspond to 4 … 20 mA False signal suppression Linearization Linear HART mode Address 0 Special pa- rameters VEGAPULS 69 • HART and accumulator pack...
  • Page 18 5 Set up with the display and adjustment module Info Menu item Parameter Device name VEGAPULS 6. Instrument version Hardware and software version Factory calibration Date date Sensor characteristics Order-specific characteristics VEGAPULS 69 • HART and accumulator pack...
  • Page 19: Supplement

    0 … +45° C (+32 … +167 °F) Ʋ Accumulator operation -20 … +60° C (-4 … +140 °F) Temperature derating accumulator capacity Ʋ +25° C (+77 °F) 100 % Ʋ -10° C (+14 °F) 50 % VEGAPULS 69 • HART and accumulator pack...
  • Page 20: Information

    Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2017 VEGA Grieshaber KG Phone +49 7836 50-0 Am Hohenstein 113...