Advertisement

Regency Horizon
WARNING: FOR OUTDOOR USE ONLY
WARNING:
If the information in these instructions
are not followed exactly, a fire
or explosion may result causing
property damage, personal injury or
loss of life.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property damage.
Read the installation, operating and
maintenance instructions thoroughly
before installing or servicing this
equipment.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-748a
HZO60 Outdoor
®
Gas Fireplace
WARNING - FOR YOUR SAFETY
What to do if you smell gas:
•Shut off gas to the appliance.
•Do not try to light any appliance.
•Extinguish any open flame.
•If odour continues, keep away from the appliance and im-
mediately call your gas supplier or fire department.
•Do not touch any electrical switch: do not use any phone
in your building.
•Immediately call your gas supplier from a neighbour's
phone.
•Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire department.
WARNING:
Do not store or use gasoline or other flammable vapours
and liquids in the vicinity of this or any other appliance.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODELS: HZO60-NG
HZO60-LP
www.regency-fire.com
08.16.17

Advertisement

Table of Contents
loading

Summary of Contents for Regency Horizon HZO60-NG

  • Page 1 Owners & Regency Horizon HZO60 Outdoor ® Installation Manual Gas Fireplace MODELS: HZO60-NG HZO60-LP www.regency-fire.com WARNING: FOR OUTDOOR USE ONLY WARNING: WARNING - FOR YOUR SAFETY If the information in these instructions What to do if you smell gas: are not followed exactly, a fire •Shut off gas to the appliance.
  • Page 2 Outdoor fireplace has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency ®...
  • Page 3: Table Of Contents

    Glass wind shield installation ........33 Operating Instructions ..........34 Lighting Procedure ............34 Shutdown Procedure ...........34 First Fire ..............34 Aeration Adjustment ............34 Copy of Lighting Plate Instructions ......35 Maintenance Instructions ..........36 Valve assembly Replacement ........37 Main Assembly ............39 Warranty ..............42 Regency Horizon® HZO60 Gas Fireplace...
  • Page 4: Copy Of Safety Decal

    Commonwealth of Massachusetts. For the State of Massachusetts, flexible connec- tors shall not exceed 36 inches in length. For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve. Regency Horizon® HZO60 Gas Fireplace...
  • Page 5: Unit Dimensions - Hzo60 Single Sided

    UNIT DIMENSIONS - HZO60 SINGLE SIDED " 1744 " 1608 " " [1535] " " 1495 ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency Horizon® HZO60 Gas Fireplace...
  • Page 6: Unit Dimensions - Hzo60 See Through

    UNIT DIMENSIONS - HZO60 SEE THROUGH " 1744 " 1608 " [1535] " " 1495 Regency Horizon® HZO60 Gas Fireplace...
  • Page 7: Important Message

    ONLY OUTDOORS IN A WELL-VENTI- 4) Inspect the burner before each use of the LATED SPACE AND SHALL NOT BE appliance for blockage and any signs of USED IN A BUILDING, GARAGE OR ANY deterioration. OTHER ENCLOSED AREA. Regency Horizon® HZO60 Gas Fireplace...
  • Page 8: Installation Checklist

    Open ventilation/airflow space comes from walls and roof/ceiling. Open floor space around the unit must not be considered ventilation/airflow space. Open side at least 25% of total wall area *SEE IMPORTANT INSTALLATION NOTES NEXT PAGE Regency Horizon® HZO60 Gas Fireplace...
  • Page 9: Outdoor Appliance Installation Summary

    This will create a pressure zone • Only Regency approved media should be used in the firebox (i.e. at the firebox and will prevent the unit from venting stones/glass) •...
  • Page 10: Minimum Clearances To Combustibles

    Wall to Wall (Minimum) must be installed on the walls of the chase, not on F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) the appliance. Notes: 0" No Hearth Required Alcove 10 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 11: Framing Dimensions Single Sided

    SCALE 1 : 5 Important Note: Two (2) ventilation grills are highly recommended for all enclosures. This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq (508 mm²) ea. Regency Horizon® HZO60 Gas Fireplace...
  • Page 12 SCALE 1 : 5 Important Note: Two (2) ventilation grills are highly recommended for all enclosures. This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq. (508 mm²) ea. 12 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 13: Mantel Clearances

    Opening Opening MANTEL LEG CLEARANCES (SINGLE SIDED AND SEE THROUGH) 16" (406mm) 16" (406mm) 9" (229mm) 9" (229mm) 5" (127mm) 5" (127mm) HZO60 5" (127mm) 5" (127mm) 9" (229mm) 9" (229mm) 16" (406mm) 16" (406mm) Regency Horizon® HZO60 Gas Fireplace...
  • Page 14: Non-Combustible Requirements

    NON-COMBUSTIBLE REQUIREMENTS 70-1/2" (1791mm) Non-combustible Material 60-3/8" (1534mm) Combustible Material 5" 5" (127mm) (127mm) 14 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 15: Framing & Finishing

    4. If material such as brick, stone, etc. extends past the faceplate depth, when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. 64-3/16" Regency Horizon® HZO60 Gas Fireplace...
  • Page 16: High Elevation

    6. When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten. 16 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 17: Unit Assembly Prior To Installation

    Nailing Area Nailing Strip tandoffs installed Note: Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 1-1/2" edge of the flange. Regency Horizon® HZO60 Gas Fireplace...
  • Page 18: Converting The Unit From Single Sided To See Thru

    3. Remove 2 screws on each side (in locations shown below) retain these screws and replace after back firebox panel is removed. Remove 4 screws 8. Proceed with framing and installation instructions to complete install. 18 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 19: Drain Installation (Recommended)

    Threaded Elbow Threaded @ 90° Reducer (PVC) (PVC) Reducer and elbow can be purchased from your local hardware store. Drain hole location at base of the unit Regency Horizon® HZO60 Gas Fireplace...
  • Page 20: Wall Switch And Battery Installation

    Strain Relief 4. Route low voltage wire and battery extension wire through the strain relief. 5. Connect low voltage wire to supplied switch, fasten switch to right side of electrical box (polarity not important). 20 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 21: Wiring Diagram

    NOTE: 4 AA batteries must be installed in the battery pack to operate the burner switch. Do not use a 9 volt battery. Optional 0.886.001 Proflame Valve Standard Main On/Off Switch or Optional Wall Switch 1 of 10 Regency Horizon® HZO60 Gas Fireplace...
  • Page 22: Optional Hardwire Kit Installation

    Once electrical wiring is complete,Secure both the GFI circuit and white blanking plate to the electrical box using 2 screws each. Diagram 1 GFI circuit Blanking Install electrical box into the outer box with 4 screws. Plate 22 | 919-774 04.03.17 Regency Horizon® HZO60 Gas Fireplace...
  • Page 23 9. HZO42/HZO60 only--Remove the front access panel by lifting up and out. 14. Turn on gas and electrical supply and test unit. 15. PTO100 Only: If a second AC adaptor is required to power a second burner, repeat steps 5-9. 919-774 04.03.17 Regency Horizon® HZO60 Gas Fireplace...
  • Page 24 The front outer cover may also be covered with finishing materials if desired. Ensure that the outer cover when using finished materials, that it may be removed if access is ever required to the GFI circuit. 24 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 25: Ac Adaptor Installation

    6. Turn on gas and electrical supply and test unit. Valve cover plate 2. Locate the 'DC supply' wire on the wiring harness,the wire will be clearly marked. DC supply wire from wiring harness AC adaptor Regency Horizon® HZO60 Gas Fireplace 919-783 05.02.17...
  • Page 26: Inner Panel Removal/ Installation

    Brackets Back Panel 3. Pop side panel out toward the burner and manoeuvre out of firebox. 6. Reverse steps to reinstall panels into unit. 4. Repeat on other side to remove opposite panel. 26 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 27: Glass Crystal / Basalt Volcanic Stones Installation

    The Burner should not be visible when the flame is out. NOTE: Basalt Volcanic Stones are NOT to be placed anywhere on the Pilot assembly area. Glass Crystals/Firebeads to be installed on the burner prior to installing stones. Regency Horizon® HZO60 Gas Fireplace...
  • Page 28: Optional Log Set Installation

    3. Install Log/Twig D on the left side of the burner, orient Log/Twig D across Log/Twig A in the same way and in a similar position as shown in Diagram 4. Diagram 4 919-764 03.06.17 28 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 29 (Mirrors Log E from previous step). Diagram 7 7. Install Log/Twig B on the left side, orient Log/Twig B in the same way and in a similar position as shown in Diagram 8. Diagram 8 Regency Horizon® HZO60 Gas Fireplace 919-764 03.06.17...
  • Page 30 Diagram 11 11. Install Log/Twig F on the left side of the burner, orient Log/Twig F in the same way and in a similar position as shown in Diagram 12. Diagram 12 30 | Regency Horizon® HZO60 Gas Fireplace 919-764 03.06.17...
  • Page 31 12. Install the opposite Log/Twig F on the right side of the burner, orient Log/Twig F in the same way and in a similar position as shown in Diagram 13 (mirror Log F as installed on the left side). Diagram 13 13. Completed install shown below. Diagram 14 Regency Horizon® HZO60 Gas Fireplace 919-764 03.06.17...
  • Page 32: Faceplate Installation

    There are 3 slots on each tab so the faceplate to accommodate different finishing materials. Trim Piece To remove - reverse steps. Install logo onto faceplate. Final Install 919-814 07.20.17 32 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 33: Glass Wind Shield Installation

    1. To install the glass wind shields - slot the glass pieces (x2) into the space between the burner tray cover and the bottom access panel. NOTE: If setting unit up as a see-through repeat procedure on opposite side of burner. Burner Tray Cover Glass Wind Shield Bottom Access panel Glass Wind Shield Installed Regency Horizon® HZO60 Gas Fireplace...
  • Page 34: Operating Instructions

    Unit will repeat step 2. SHUTDOWN PROCEDURE 1. Turn ON/OFF switch. 2. If service is to be performed - you must discon- nect both sources of power to the unit, the main power and battery. 34 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 35: Copy Of Lighting Plate Instructions

    THIS INSTRUCTION PLATE c) L'unité répètera l'étape 2. c) Unit will repeat step 2. appliance. 918-892a Jan 19/10: Created draft for approval Feb 16/10: Changed size of decal xcept er than cut clearance. r approval decal Regency Horizon® HZO60 Gas Fireplace...
  • Page 36: Maintenance Instructions

    Failure to do this will result in burn stains on panels which you will be unable to remove. 4. The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.
  • Page 37: Valve Assembly Replacement

    6. Remove the two (2) burner end caps by lifting out as shown. 14. Remove orange EV1 wire and ground wire connected to the gas valve. 15. Remove green EV2 wire connected to the gas valve. Ground wire location (Ground wire not shown) Regency Horizon® HZO60 Gas Fireplace...
  • Page 38 19. Replace valve assembly gasket if necessary. 20. Rotate HI/LO modulating valve all the way to the left for HI position. 21. Install new valve assembly and reverse steps 11-1. 22. Test gas connections for leaks. 38 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 39: Main Assembly

    Stainless Side Panel 646-116/F Burner tray cover 646-115 Stainless cover plate 326-034 Panel Clip *See next page 940-488/P Front Glass 646-114 Stainless Back Panel 646-113 Rear Panel 646-125 Rear Panel Bracket 646-108 Glass Clip Part Not Shown Regency Horizon® HZO60 Gas Fireplace...
  • Page 40: Parts List

    GFCI Outlet 15 Amp 125 Volt Duplex (Hardwire Kit) 911-233 Blank Adaptor Plate White (Hardwire Kit) 911-088 Box Switch Rectangular Two Gang (Hard- wire Kit) 911-090/P Power Adaptor AC/DC 7V 0.584.851 (Hardwire Kit) 910-178 Grommet Strain Relief (Hardwire Kit) 40 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 41 Regency Horizon® HZO60 Gas Fireplace...
  • Page 42: Warranty

    All claims must be complete and provide full details as requested by FPI to receive consideration for evaluation. Incomplete claims may be rejected. Revision Date: December 2016 Regency Outdoor Products Warranty 42 | Regency Horizon® HZO60 Gas Fireplace...
  • Page 43 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: December 2016 Regency Outdoor Products Warranty Regency Horizon® HZO60 Gas Fireplace...
  • Page 44 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 45 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 48 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Horizon is a trademark of FPI Fireplace Products International Ltd. © Copyright 2017, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Horizon hzo60-lp

Table of Contents