Regency Plateau PT030-NG1 Owners & Installation Manual

Outdoor decorative gas appliance

Advertisement

Quick Links

Regency Plateau
Decorative Gas Appliance
www.regency-fi re.com
WARNING:
If the information in these instructions
are not followed exactly, a fire
or explosion may result causing
property damage, personal injury or
loss of life.
WARNING:
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property damage.
Read the installation, operating and
maintenance instructions thoroughly
before installing or servicing this
equipment.
Installation and service must be
performed by a qualifi ed installer,
service agency or the gas supplier.
Tested by:
919-136
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
PTO30 Outdoor
WARNING - FOR YOUR SAFETY
What to do if you smell gas:
•Shut off gas to the appliance.
•Do not try to light any appliance.
•Extinguish any open fl ame.
•If odour continues, keep away from the appliance and im-
mediately call your gas supplier or fi re department.
•Do not touch any electrical switch: do not use any phone
in your building.
•Immediately call your gas supplier from a neighbour's
phone.
•Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fi re
department.
WARNING:
Do not store or use gasoline or other fl ammable vapours
and liquids in the vicinity of this or any other appliance.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
Models: PTO30-NG1 / PTO30-LP1
WARNING: FOR OUTDOOR USE ONLY
Owners &
02/21/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Plateau PT030-NG1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Plateau PT030-NG1

  • Page 1 Owners & Regency Plateau PTO30 Outdoor ™ Installation Manual Decorative Gas Appliance Models: PTO30-NG1 / PTO30-LP1 WARNING: FOR OUTDOOR USE ONLY www.regency-fi re.com WARNING: WARNING - FOR YOUR SAFETY If the information in these instructions What to do if you smell gas: are not followed exactly, a fire •Shut off gas to the appliance.
  • Page 2 To the New Owner: Congratulations! ® You are the owner of a state-of-the-art Outdoor Decorative Gas Appliance by REGENCY . The Plateau™ PTO30 Outdoor decorative gas appliance has been designed to provide you with all the warmth and charm of a fi re at the fl ick of a switch. The Plateau™ PTO30 Outdoor Decorative Gas Appliance has been approved by Warnock Hersey/Intertek for both safety and effi...
  • Page 3: Table Of Contents

    PTO60 Wiring Diagram ..........18 (PtO60 = 2 x pto30 ASSEMBLED END-TO-END) ..18 Glass Crystal / Basalt volcanic stones installation ..19 Optional Log Set Installation........20 NOTE: PTO60 is two PTO30 units assembled end to end. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 4: Safety Label

    Commonwealth of Massachusetts. For the State of Massachusetts, fl exible connec- tors shall not exceed 36 inches in length. For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 5: Dimensions

    DIMENSIONS PTO30 UNIT DIMENSIONS 37-9/16" (953mm) TOP VIEW 33-1/4" (844mm) 8-1/4" (210mm) 36-7/16" (932mm) SIDE VIEW END VIEW Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 6: Pto60 Unit Dimensions

    DIMENSIONS PTO60 UNIT DIMENSIONS NOTE: PTO60 is two PTO30 units assembled end to end (see PT060 assembly for more details). 66-7/16" (1688mm) TOP VIEW 8-1/4" (210mm) SIDE VIEW END VIEW Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 7: Important Message

    THIS APPLIANCE SHALL BE USED ONLY OUTDOORS IN A WELL-VENTI- LATED SPACE AND SHALL NOT BE USED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED AREA. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 8: Installation Checklist

    30% or more in total of the remaining wall area is open and unrestricted. Open side at least 25% of total wall area *SEE IMPORTANT INSTALLATION NOTES NEXT PAGE Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 9: Important Things To Remember

    fi rebox opening. This will create a pressure zone • Only Regency approved media should be used in the fi rebox (i.e. at the fi rebox and will prevent the unit from venting stones/glass) •...
  • Page 10: Minimum Clearances To Combustibles

    Unit Base to Combustible E1: Alcove Width 30" 84"(2134mm) Wall to Wall (Minimum) E2: Alcove Width 60" 100" (2540mm) F: Alcove Depth 60" (1524mm) Front to Back Wall (Maximum) Notes: 0" No Hearth Required Alcove Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 11: Inner Framing Dimensions (Required)

    Consideration should be given to weather / elements TOP VIEW when choosing framing materials (ie. treated lumber, steel stud). 37-15/16" (964mm) 8-3/4" (222mm) SIDE VIEW END VIEW PTO60 66-15/16" (1700mm) TOP VIEW 66-15/16" (1700mm) 8-3/4" (222mm) SIDE VIEW END VIEW Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 12: Finishing

    Determine the thickness of the fi nishing material before adjusting the nailing strips. 1/2" 2-3/8" 1/8" Increments 1/4" Increments OPTIONAL FINISHING TRIM Optional fi nishing trim is supplied with the PTO30 - place fi nishing trim on unit between unit and fi nishing material. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 13: High Elevation

    (clockwise) with a 1/8" fl at screwdriver. a soap and water solution or gas leak detector. Note: Screw should be snug, but do not over Do not use open fl ame for leak testing. tighten. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 14: Pto60 Assembly

    2. Remove 9 screws in locations shown below to remove burner tray (re- move from both units). 3. Lift burner tray off-burner tube can remain in place. 6. Install units together into framing (refer to framing section). Secure in place with nailing strips. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 15: Pto30 Wall Switch And Battery Installation

    Strain Relief 4) Route low voltage wire and battery extension wire through the strain relief. 5) Connect low voltage wire to supplied switch, fasten switch to right side of electrical box (polarity not important). Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 16: Pto60 Wall Switch And Battery Installation

    11) Place switch in OFF position until fi nal installation is complete. Note: Ensure the battery extension wires are approx. 8" in length inside the electrical box. This excess will ensure ease of battery replacement and servicing in the future. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 17: Pto30/Pt060 Drain Installation (Recommended)

    Cut notches into the top of the coupling reducer to prevent water pooling. Threaded Elbow Threaded @ 90° Reducer (PVC) (PVC) View from under- side of unit. Reducer and elbow can be purchased from your local hardware store. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 18: Pto30 Wiring Diagram

    The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with theNational Electrical Code, ANSI/NFPA 70, if applicable. PTO60 WIRING DIAGRAM (PTO60 = 2 X PTO30 ASSEMBLED END-TO-END) Battery Holder ON/OFF Switch Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 19: Glass Crystal / Basalt Volcanic Stones Installation

    The Burner should not be visible when the fl ame is out. NOTE: Basalt Volcanic Stones are NOT to be placed anywhere on the Pilot assembly area. Glass Crystals to be installed on the burner prior to installing stones. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 20: Optional Log Set Installation

    Diagram 3 3) Install log E on the burner as shown below. Orient log E across log D in the same way and in a similar position as shown in Diagram 4. Diagram 4 Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 21 6) Install log C on the left side of the burner as shown below. Orient log C in the same way and in a similar position as shown in Diagram 7. Diagram 7 Final Install Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 22: Optional Glass Surround Installation

    Repeat process on other end. Press down fi rmly from to secure glass surround in position. Use care not to scratch surfaces. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 23 Top / Bottom (A) x 2 Vertical Supports - Tall (B) x 8 Vertical Supports - Short (C) x 6 Base (D) x 1 Short Brace (E) x 4 Header (F) x 2 Vents Wafer Screws Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 24 Diagram 6 - Outside Part B Part A Diagram 3 3. Attach inside tall vertical supports (Part B) to short vertical supports (Part C) with one (1) screw each. Part B Part C Diagram 4 Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 25 9. Secure all tall vertical supports (Part B) to Top and Bottom Frame (Part A) with three (3) screws each, Diagram 13 & 14 - Part F If installing optional panels or propane tank drawer - continue on to next Diagram 10 section. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 26 Flattened Tabs Diagram 3 - Bend tabs fl at, panels is supported on headers. 4. Install top panel with six (6) screws in locations shown below. Diagram 2 - Top Panel screw locations Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 27 When using a LP tank - a minimum 1”(25mm) gap must be maintained at all times, between the floor and base of unit. 1” Max. (Refer to owners manual) 919-031 2” Min. Diagram 1 Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 28 1 level tape measure 377-910 CONTENTS: Top / Bottom (A) x 2 Vertical Supports - Corner (B) x 4 Vertical Supports - Inner (C) x 6 Vertical Supports - Outer (C) x 4 Wafer Screws Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 29 4. Install four (4) outer vertical supports - secure each support with two (2) screws to top frame and two (2) screws to bottom frame. Diagram 3 - Corner supports with top frame Diagram 6 - Outside vertical supports Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 30: Operating Instructions

    OFF switch. c. Unit will repeat step 2. SHUTDOWN PROCEDURE 1. Turn ON/OFF switch. 2. If service is to be performed - you must discon- nect power to the unit, by removing the battery pack. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 31: Copy Of Lighting Plate Instructions

    After approximately 2 seconds turn on ON/OFF switch. a c c o m p a n y i n g THIS INSTRUCTION PLATE c) L'unité répétera l'étape 2. c) Unit will repeat step 2. appliance. 918-892a Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 32: Maintenance

    Failure to do this will result in burn stains on panels which you will be unable to remove. 5. The heater is fi nished in a heat resistant paint and should only be refi nished with heat resistant paint. Regency ®...
  • Page 33: Valve Assembly Replacement

    14. Rotate HI/LO modulating valve all the way to the left for HI position. 9. Remove green EV2 wire connected to the gas valve. 15. Install new valve assembly and reverse steps 11-1. 16. Test gas connections for leaks. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 34: Parts

    Valve Tray 377-027 Burner Mount 377-047 Components Cover 377-028 Burner Tray End 377-048 Pilot Shield support 377-030 Offset Bracket 377-054 Drainage Bracket 376-512 Electronic Assembly NOTE: PTO60 is two PTO30 units assembled end to end. Regency Plateau™ PTO30 Outdoor Gas Fireplace...
  • Page 35: Warranty

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited warranty to the original purchaser of a Regency ®...
  • Page 36 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency, Regency Plateau are trademarks of FPI Fireplace Products International Ltd. © Copyright 2013, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Plateau pt030-lp1

Table of Contents