Fisher 4195 KB Series Instruction Manual page 8

Gauge pressure controllers
Table of Contents

Advertisement

4195KA, KB, and KC Series
BOURDON TUBES
BOURDON TUBES
Psig
0 to 30
0 to 60
0 to 100
0 to 200
0 to 300
0 to 600
0 to 1000
0 to 1500
U.S. units
U.S. units
0 to 3000
0 to 5000
0 to 8000
0 to 10,000
0 to 600
0 to 1000
0 to 1500
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
0 to 25
Metric units
0 to 40
0 to 60
0 to 100
0 to 160
0 to 300
0 to 550
0 to 600
0 to 40
0 to 60
0 to 100
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 30 psig (0 to 2 bar) sensing element is used
and the minimum span of 15 psig (1 bar) is set, the process indication can be calibrated to a range of –30 inch Hg to 0 psig (–1 to 0 bar), 0 to 15 psig (0 to 1 bar), 15 to 30 psig (1 to 2
bar), 27 to 42 psig (2 to 3 bar) or any value between the operating range minimum and maxi mum values.
2. Travel stops should be used when the maximum or minimum process pressure will be 5% over or under the calibrated range. For example, a 0 to 30 psig (0 to 2 bar) sensing
element is calibrated for 10 to 30 psig (0.7 to 2 bar), the desired range. The minimum expected pressure is 0 psig and the maximum expected pressure is 40 psig (2.8 bar). Travel
stops must be used to prevent excessive overtravel and undertravel since the maximum allowable overpressure and underpressure is higher than 5% of the 20 psig (1.4 bar) span
which is 1 psig (70 mbar).
3. Bourdon tube without travel stops may be pressured to this value without permanent zero shift.
4. Bourdon tube with travel stops set may be pressured to this value without permanent zero shift.
Table 1–5. Optional Process Connections
PSIG INPUT
PSIG INPUT
BAR INPUT
BAR INPUT
RANGE
RANGE
Up to
Up to
or
0 to 5000
0 to 400
female
0 to 5000 to
0 to 400 to
1/2-inch NPT female
0 to 10,000
0 to 600
0 to 5000 to
0 to 400 to
1/2-inch NPT male
0 to 10,000
0 to 600
1–8
Table 1–4. Process Sensor (Bourdon T ube) Pressure Ratings and Materials
(1)
SPAN
Minimum
Maximum
Psig
Psig
15
30
30
60
50
100
100
200
150
300
300
600
750
1000
1100
1500
2200
3000
3700
5000
6000
8000
7500
10,000
300
600
750
1000
1100
1500
1
2
2
4
2
4
3.5
7
7
14
10
20
20
40
20
40
55
70
76
100
160
200
250
350
420
550
520
700
20
40
55
70
76
100
CONNECTION
Size
Material
Steel or
1/2-inch NPT male
1/2-inch NPT
stainless
steel
Stainless steel
Stainless steel
(2)
OPERATING RANGE
(3)
Minimum
Maximum
Inch Hg
Psig
–30
42
–30
84
–30
140
–30
280
–30
420
0
840
0
1300
0
1950
0
3900
0
6000
0
9600
0
12,000
0
840
0
1300
0
1950
Bar
–1
3
–1
6
–1
6
–1
10
–1
20
–1
30
0
60
0
60
0
90
0
135
0
270
0
420
0
670
0
830
0
60
0
90
0
135
T able 1–6. Supply Pressure Data
Output Signal
Range
Psig
Psig
3 to 15
6 to 30
Bar
Bar
0.2 to 1.0
0.4 to 2.0
1. If this pressure is exceeded, control may be impaired.
2. If this pressure is exceeded, damage to the controller may result.
OPERATING
OPERATING
STANDARD
STANDARD
(4)
(4)
LIMITS
MATERIAL
MATERIAL
Psig
48
96
160
320
480
S31600 (316 SST)
960
1500
2250
4500
7000
11,200
N09902 Nickel Alloy
14,000
(Ni-Span C)
960
K-Monel
1500
(for NACE)
2250
3.3
6.6
6.6
11
22
33
S31600 (316 SST)
66
66
103
155
310
482
772
N09902 Nickel Alloy
965
(Ni-Span C)
66
K-Monel
103
(for NACE)
155
Normal Operating
Maximum Pressure
(1)
Supply Pressure
Limit
20
35
1.4
2.4
(2)
40
40
2.8
2.8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4195 kc series4195 ka series

Table of Contents