Fisher 4195 KB Series Instruction Manual page 7

Gauge pressure controllers
Table of Contents

Advertisement

Table 1–3. Process Sensor (Capsular Element) Pressure Ratings (Continued)
CAPSULE
CAPSULE
MATERIAL
Positive pressure
U.S. units
S31600
(316 SST)
Positive pressure
Positive pressure
Metric units
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 5 psig (0 to 350 mbar) sensing element is used
and the minimum span of 2.5 psig (175 mbar) is set, the process indicaion can be calibrated to a range of –10 inch Hg to –6 inch Hg (–340 mbar to –203 mbar), 0 to 2.5 psig (0 to 172
mbar), 2.5 to 5 psig (172 to 345 mbar), 4.5 to 7 psig (305 to 480 mbar), or any value between minimum and maximum values of operating range.
2. Capsules with the travel stops set may be pressured to this value without permanent zero shift.
CAPSULAR
CAPSULAR
STANDARD RANGES
0 to 60 inch wc
0 to 5 psig
0 to 10 psig
3 to 15 psig
0 to 15 psig
0 to 20 psig
6 to 30 psig
0 to 30 psig
–5 to 0 inch Hg
–10 to 0 inch Hg
Vacuum
–20 to 0 inch Hg
–30 to 0 inch Hg
–30 to 30 inch wc
–5 inch Hg to 2.5 psig
–10 inch Hg to 5 psig
Compound
Compound
–15 inch Hg to 7.5 psig
–20 inch Hg to 10 psig
–30 inch Hg to 15 psig
0 to 150 mbar
0 to 400 mbar
0 to 0.6 bar
0.2 to 1 bar
0 to 1 bar
0 to 1.4 bar
0 to 1.6 bar
0.4 to 2 bar
0 to 2 bar
–150 to 0 mbar
–340 to 0 mbar
Vacuum
–400 to 0 mbar
–0.6 to 0 bar
–1 to 0 bar
–50 to 100 mbar
–175 to 175 mbar
–150 to 250 mbar
–0.2 to 0.4 bar
Compound
Compound
–0.4 to 0.6 bar
–0.6 to 0.8 bar
–1 to 0.6 bar
–1 to 1 bar
4195KA, KB, and KC Series
(1)
SPAN
Min
Max
40 inch wc
60 inch wc
2.5 psig
5 psig
5 psig
10 psig
6 psig
12 psig
7.5 psig
15 psig
10 psig
20 psig
12 psig
24 psig
15 psig
30 psig
2.5 inch Hg
5 inch Hg
5 inch Hg
10 inch Hg
10 inch Hg
20 inch Hg
15 inch Hg
30 inch Hg
40 inch wc
60 inch wc
2.5 psig
5 psig
5 psig
10 psig
7.5 psig
15 psig
10 psig
20 psig
15 psig
30 psig
100 mbar
160 mbar
350 mbar
700 mbar
0.35 bar
0.7 bar
0.4 bar
0.8 bar
0.5 bar
1 bar
0.7 bar
1.4 bar
1 bar
2 bar
0.8 bar
1.6 bar
1 bar
2 bar
85 mbar
170 mbar
170 mbar
340 mbar
350 mbar
700 mbar
0.35 bar
0.7 bar
0.5 bar
1 bar
100 mbar
160 mbar
175 mbar
350 mbar
350 mbar
700 mbar
0.35 bar
0.7 bar
0.5 bar
1 bar
0.7 bar
1.4 bar
1 bar
2 bar
1 bar
2 bar
OPERATING RANGE
OPERATING
OPERATING
Min
Max
–5 inch Hg
2.5 psig
3.75 psig
–10 inch Hg
5 psig
7.5 psig
–20 inch Hg
10 psig
15 psig
–30 inch Hg
15 psig
22.5 psig
–30 inch Hg
15 psig
22.5 psig
–30 inch Hg
20 psig
30 psig
0 psig
30 psig
45 psig
–30 inch Hg
30 psig
45 psig
–5 inch Hg
2.5 psig
3.75 psig
–10 inch Hg
5 psig
7.5 psig
–20 inch Hg
15 psig
15 psig
–30 inch Hg
15 psig
22.5 psig
–5 inch Hg
2.5 psig
3.75 psig
–10 inch Hg
5 psig
7.5 psig
–20 inch Hg
10 psig
15 psig
–30 inch Hg
15 psig
22.5 psig
–30 inch Hg
20 psig
30 psig
–30 inch Hg
30 psig
45 psig
–170 mbar
170 mbar
255 mbar
–700 mbar
700 mbar
1 bar
–0.7 bar
0.7 bar
1 bar
–1 bar
1 bar
1.5 bar
–1 bar
1 bar
1.5 bar
–1 bar
1.4 bar
2 bar
–1 bar
2 bar
3 bar
0 bar
2 bar
3 bar
–1 bar
2 bar
3 bar
–170 mbar
170 mbar
255 mbar
–340 mbar
340 mbar
510 mbar
–0.7 bar
0.7 bar
1 bar
–0.7 bar
0.7 bar
1 bar
–1 bar
1 bar
1.5 bar
–170 mbar
170 mbar
255 mbar
–340 mbar
340 mbar
510 mbar
–700 mbar
700 mbar
1 bar
–0.7 bar
0.7 bar
1 bar
–1 bar
1 bar
1.5 bar
–1 bar
1.4 bar
2 bar
–1 bar
2 bar
3 bar
–1 bar
2 bar
3 bar
(2)
(2)
LIMIT
1–7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4195 kc series4195 ka series

Table of Contents