3.5.5

ATX Mode

By connecting an ATX power supply with VCC and 5VSB, PWR_OK is set to low level and VCC is off. Press the Power Button to
enable the ATX PSU setting PWR_OK to high level and powering on VCC. The ATX PSU is controlled by the PS_ON# signal
which is generated by SUS_S3# via inversion. VCC can be 8.5V - 20V in ATX Mode. On Computer-on-Modules supporting a
wide range input down to 4.75V the input voltage shall always be higher than 5V Standby (VCC > 5VSB).
State
PWRBTN#
G3
x
S5
high
S5 → S0
PWRBTN Event
S0
high
3.5.6

Single Supply Mode

In single supply mode (or automatic power on after power loss) without 5V Standby the module will start automatically
when VCC power is connected and Power Good input is open or at high level (internal PU to 3.3V). PS_ON# is not used in
this mode and VCC can be 8.5V - 20V.
To power on the module from S5 state press the power button or reconnect VCC. Suspend/Standby States are not
supported in Single Supply Mode.
State
PWRBTN#
G3
x
G3 → S0
high
S5
high
S5 → S0
PWRBTN Event
Signals marked with "x" are not important for the specific power state. There is no
difference if connected or open.
All ground pins have to be tied to the ground plane of the carrier board.
21
PWR_OK
V5_StdBy
x
0V
low
5V
low → high
5V
high
5V
PWR_OK
x
open / high
open / high
open / high
COMe-cHL6 / Product Specification
PS_ON#
VCC
x
0V
high
0V
high → low
0 V→ VCC
low
VCC
V5_StdBy
VCC
x
0
x
connecting VCC
x
VCC
x
reconnecting VCC