Important: Retain these instructions
These instructions shall be used by trained service
personnel only.
If the equipment is used in a manner not
specified by these instructions, the protection provided by the
equipment may be impaired.
CoNTENTs
1

Box Contents .................................................................1

2

Storing ...........................................................................1

3

Installation .....................................................................1

1
Box CoNTENTs
3
INsTAllATIoN
labels used on IQ4E
Caution, consult
!
documentation
230 Vac input
power connector
RS232 Local
Supervisor Port
Auxiliary supply
output connector
USB
(for future use)
Bias switch
(/XNC only)
Ethernet indicators
and connector
Auxiliary supply
output connector
Dimensions
1
IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
IQ4E/.. Installation
Instructions - Mounting
(TG201338)
IQ4/IC/TERM
I/O Bus Terminator
Caution, possibility
of electric shock
Wallbus
connector
Universal input
n
n
n
connector
Terminator switch
(/XNC only)
RS-485
(/XNC only)
Trend current
loop connector
84
85
86
87
Analogue output
n
connector
n
n
192.5 mm (7.55")
Installation Instructions - Mounting
GB
DE
DK
ES
PL
IT
NL
NO
https://partners.trendcontrols.com
4
Removing From Din Rail ............................................11
5
Field Maintenance .......................................................12
6
Disposal .......................................................................12
7
End User Licence Agreement .....................................12
2
sToRING
-25°C
+60°C
(-13°F)
(+140°F)
Note: For temperatures below 0°C (32°F) special care must be
taken that there is no condensation on or within the unit.
It is recommended that the installation should comply
with the local electrical safety installation practices (e.g.
HSE Memorandum of Guidance on Electricity at Work
Regulations 1989, USA National Electric Code).
Any connected devices must be insulated from mains by
reinforced insulation.
WARNING Removal of cover exposes dangerous
voltages.
WARNING To reduce the risk of electrical shock or fire
do not interconnect the output of different Class 2 circuits.
USB Local
Engineering Port
Power indicator
LAN OK indicator
53.5 mm (2.11")
58.5 mm (2.3")
IQ4E/..
Controller
FI
FR
SE
RU
0
90%RH
H O
2
Service button/
indicator
Watchdog indicator
I/O Bus indicator
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQ4E and is the answer not in the manual?

Questions and answers

Mathew Hawkins
January 21, 2025

I can't access our boiler controls via our Trend iQ4E system. It won't let me gain access through ethernet connection with the IP address provided.

1 comments:
Mr. Anderson
May 14, 2025

To troubleshoot access issues with the TREND iQ4E boiler controls via Ethernet connection, follow these steps:

1. Check Physical Connections: Ensure Ethernet cables are securely connected to the controller and network switch/router.

2. Verify IP Configuration: Make sure the controller has a valid IP address compatible with your network settings.

3. Ping the Controller: From a computer on the same network, try pinging the controller’s IP address to confirm it is reachable.

4. Check BACnet Over IP Settings: Confirm BACnet over IP is enabled on the controller since it is supported by default.

5. Review Controller Variant: Some variants may have different I/O capabilities; ensure the correct model is used for boiler control.

6. Inspect Current Loop Plan Option: If using Trend communications over current loop, verify that this is properly configured and not conflicting with Ethernet settings.

7. Examine Power Supply: Confirm the controller is powered correctly and the power connections are secure.

8. Use Trend Tools: If available, use Trend network tools/software to scan for and access the controller over the network.

If these steps do not resolve the issue, further investigation into network configuration or controller diagnostics may be needed.

This answer is automatically generated

Summary of Contents for TREND IQ4E

  • Page 1 Power indicator Watchdog indicator Auxiliary supply Analogue output LAN OK indicator I/O Bus indicator output connector connector Dimensions 53.5 mm (2.11”) 192.5 mm (7.55”) 58.5 mm (2.3”) IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 2 0%RH 90%RH Must be installed in an enclosure rated to at least IP20 or equivalent IQ4E/.. DIN Rail end stop IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 3 DIN rail must be earthed (grounded) Attach large Barcode label to Panel TREND IQ41x IQ4e Q3B_X73080031 SERIAL No. I QECO: Q3 B_ X7 3 0 8 0 0 3 1 open Rotating Covers IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 4 Connect Ethernet (if required) Trend Ethernet Products Engineering Guide (TE200369) Hub / Switch Router RJ45 RJ45 Standard Ethernet cable (Cat 5e twisted pair) maximum 100 m (109 yds) IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 5 Loop powered (using AUX output supply - see step 11) Common (C) terminal is linked internally to AUX External supply common - no connection required Power Supply ensure correct ensure correct polarity polarity IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 6 Maximum current: Terminals 70 & 71 (Load A+B) = 120 mA Terminal 72 (Load C) = 120 mA or any ‘C’ terminal Load A Load B Load C IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 7 If a network is not fitted a loop back must be fitted as shown. 2 wire system 4 wire system panel/enclosure additional terminals ground panel/enclosure ground additional terminals IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 8 Cabinet A Cabinet B a resistor matched to the cable characteristic impedance (i.e. ±1%, ¼ Watt, range 100 to 130 ohms). If the IQ4E is at one end RS-485 of a 120 ohm cable, switch in its built-in terminator, otherwise switch it out and fit a resistor at that end of the cable;...
  • Page 9 14 (subject to power loading - refer to device documentation). IQ4 Configuration Manual (TE201263) Example wiring e.g RD-WMB Polarity independent IQ4E IQ4E to additional wallbus devices IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 10 Install and Connect I/o Modules (if required) Remove I/O bus terminator from IQ4E and retain for use on the last IQ4/IO module (see below) Connecting I/o modules to the IQ4E I/o bus IQ4E is compatible with I/O modules from the IQ4/IO and XCITE/IO ranges.
  • Page 11 IQ4E/.. Installation Instructions - Confi guring (TG201339) IQ4/IO/.. Installation Instructions - Confi guring (TG201343) XCITE/IO/.. Installation Instructions - Confi guring (TG201161) REMoVING FRoM DIN RAIl Remove from DIN rail (0.078") IQ4E/.. Installation Instructions - Mounting TG201338 Issue 4, 19-Jan-2016. Applies to v3.33.
  • Page 12 Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited. Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes.

Table of Contents

Save PDF