Fitting The Cover - Triton T80 PRO-FIT Installation And Operating Instructions Manual

Electric shower
Table of Contents

Advertisement

SECTION
7
IMPORTANT: When connecting the cable fully
tighten the terminal block screws and make sure
that no cable insulation is trapped under the
screws. Loose connections can result in cable
overheating.
NOTE: The supply cable earth conductor must
be sleeved. The outer sheath of the supply cable
must be stripped back to the minimum.
• The use of connections within the unit or
other points in the shower circuit to supply
power to other equipment i.e. extractor fans,
pumps etc. will invalidate the guarantee.
• DO NOT switch on the electricity supply
until the shower cover has been fitted.
NOTE: The elements on UK models are to
240V specification and will give a lower kW
rating if the voltage supply is below 240V.
SECTION
8

FITTING THE COVER

Figures 22, 23, 24 and 25 (on page 19) show
the correct control knob position when replacing
the cover.
• Check to ensure that the wiring is not
trapped and fit the cover squarely to the
backplate and guide into position so that the
knobs locate correctly into the spindles.
• Should any difficulty arise, recheck the
points above.
• While applying slight pressure to the cover,
secure in position with the retaining screws.
Installation - FITTING THE COVER
COVER RETAINING SCREWS
ONLY the SUPPLIED SCREWS should be
used. The use of none supplied screws WILL
invalidate product specifications & warranty.
18
Continued
check list
WARNING