Fujitsu IP-HE950 Hardware User's Manual page 63

Table of Contents

Advertisement

IP-HE950 Hardware User's Guide
No.
Class
Status
5
The INDWN
LED lights up
in orange.
6
The INDWN
7
LED is blinking
in orange.
8
9
10
No video is
output at the
decoder.
11
(Black screen)
12
13
14
15
The monitor of
the decoder
16
displays an all
blue or gray
screen.
17
18
19
Check
Is the audio/video output unit selected as
input (e.g., camera) operating normally?
Is this unit correctly connected to the
audio/video output unit?
(Example: Analog signals are connected to
the SDI signal input of this unit.)
Does the set input audio/video format on
this unit match the format of the
audio/video output unit (e.g., camera)?
(Example: Although 2160p is the input
setting on this unit, 1080p signals are
input.)
Does the set input audio/video format on
this unit match the format of the
audio/video output unit (e.g., camera)?
(Example: Although 59.94 Hz is the input
setting on this unit, the output unit is set to
50 Hz.)
Is the monitor connected to the decoder
operating normally?
Is the decoder operating normally?
Is the decoder correctly connected to the
monitor?
Has an alert been generated on the
decoder?
Does the decoder display color bars or a
gray screen when nothing is input to the
video input of this unit? (Note that this
operation generates INDVN. Confirm that
there will be no operational problems
before performing the operation.)
Is the RDY LED blinking in green?
Is the RDY LED blinking in orange?
Is the ALM LED blinking?
Has encoding begun?
Can the paired unit (decoder) start
encoding?
Are the Stream out settings correct?
Is the network operating normally?
Check the power supply and the operation of the
audio/video output unit selected as input.
Confirm that the connection between this unit and the
audio/video output unit is correct, and check for
problems in the cable.
Check whether your preferred audio/video format is set
as the format of this unit and the format of the output
unit.
Check whether your preferred audio/video format is set
as the format of this unit and the format of the output
unit.
Check the operation of the monitor.
Check the operation of the decoder.
Check the connection between the decoder and the
monitor.
If so, refer to the user's guide of the decoder or other
such documents, and take corrective action.
If color bars or a gray screen appears, the network and
the decoder seem to be operating normally. Confirm the
correct video input to this unit.
The unit is booting up.
Wait until the RDY LED turns green.
The unit started in maintenance mode.
Restart the unit.
The blinking ALM LED may indicate an IP address
acquisition failure. Check the IP address setting. (For
details, refer to the IP-HE950 Software User's Guide.)
Set the encoder to start encoding.
Set the decoder to start decoding.
Referring to the IP-HE950 Software User's Guide,
check whether the Stream out settings are correct on
this unit and the encoder.
Refer to the "Network" section in this table.