Advertisement

Quick Links

32/64 Pumps
Customer Product Manual
Part 106 588D
NORDSON CORPORATION
AMHERST, OHIO
USA
D
D

Advertisement

Table of Contents
loading

Summary of Contents for Nordson 32

  • Page 1 32/64 Pumps Customer Product Manual Part 106 588D NORDSON CORPORATION AMHERST, OHIO...
  • Page 2: Issued

    Amherst, OH 44001 Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date 1995. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice.
  • Page 3: Table Of Contents

    ......... . . 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 4 ..........Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 5 ......7-22 6. 10/20:1 and 16/32:1 Hydraulic Sections .....
  • Page 6 ......8-23 10/20:1 and 16/32:1 Hydraulic Section Packing Gland G ..
  • Page 7 Section 1 Safety A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 8 Safety A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 9: Safety Symbols

    Safety Section 1 Safety This section contains general safety instructions for using your Nordson 1. Introduction equipment. Task- and equipment-specific warnings are included in other sections of this manual where appropriate. Note all warnings and follow all instructions carefully. Failure to do so may result in personal injury, death, or property damage.
  • Page 10 Failure to observe this warning may result in serious injury or death. WARNING: Injection. Do not point this device at yourself or other personnel. Failure to observe this warning may result in serious injury or death. A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 11: Intended Use

    Unintended uses may result from taking the following actions: making changes to equipment that have not been recommended or described in this manual or using parts that are not genuine Nordson replacement parts failing to make sure that auxiliary equipment complies with approval...
  • Page 12: Installation

    Safety Read the installation section of all system component manuals before 5. Installation installing your Nordson equipment. A thorough understanding of system components and their requirements will help you to install this equipment safely and efficiently. WARNING: Failure to follow these safety procedures can result in personal injury or death.
  • Page 13: Operation

    Make sure all devices are fully functional. Do not operate the system if these devices are not working properly. Do not deactivate or bypass automatic safety interlocks, locked-out electrical disconnects, or pneumatic valves. A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 14 An arc can cause a fire or explosion. Keep parts of the body or loose clothing away from rotating parts. Remove personal jewelry and cover or tie back long hair. A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 15: Less-Obvious Dangers

    A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 16: Action In The Event Of A System Or Component Malfunction

    Allow only qualified personnel to perform maintenance, troubleshooting, 9. Maintenance and Repair and repair tasks. Only persons who are properly trained and familiar with Nordson equipment are permitted to service this equipment. Always wear appropriate protective clothing and use safety devices when working on this equipment.
  • Page 17 Never troubleshoot the power supply without first disconnecting all external power supplies and discharging the high-voltage capacitors with an insulated screwdriver. Ground electrodes and electrostatic cable ends before touching them. A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 18: Material And Solvent Precautions

    MSDS for the injected fluid and for any additives, such as solvents, that are in the injected fluid. Also, Nordson recommends that you carry a National Safety Equipment Manufacturers Association (NSEMA) wallet card to give to emergency medical staff in the event of an injection injury. These cards are supplied with the equipment.
  • Page 19 Use nonhalogenated solvents. Contact your solvent supplier to determine whether your existing materials and solvents contain halogenated hydrocarbons or to obtain a suitable, nonhalogenated hydrocarbon solvent for cleaning and flushing your system. A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 20: Manual

    Contact your coatings, solvent, or adhesive supplier for a nonhalogenated solvent to thoroughly flush the entire system before operating it. If you must continue to use halogenated hydrocarbon solvents, consult your Nordson representative about compatible Nordson components. A1EN−03−[SF−LIQD]−3 Issued 11/95...
  • Page 21: Disposal

    Methylene Chlorobromide Freon Methylene Chloride Propyl Iodide 1-1-1 Trichloroethane Monochlorobenzene Orthodichlorobenzene Perchloroethylene Trichloroethylene Dispose of equipment and materials used in operation and cleaning 11. Disposal according to your local regulations. A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 22 1-14 Safety A1EN−03−[SF−LIQD]−3 Issued 11/95 E 1995 Nordson Corporation All rights reserved...
  • Page 23: Safety Label

    Before servicing, cleaning, or removal of any part, set trigger lock on gun, and always shut off power source; then carefully release pressure in fluid portions of the system. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 24 1-16 Safety 12. Safety Label (contd.) 0112006A Fig. 1-1 Safety Label Location (Typical) Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 25 Section 2 Description 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 26 Description Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 27: Introduction

    See Figure 2-1. The PMP Series 32/64 pumps are positive displacement 1. Introduction demand-type units. They are available in 2:1, 4:1, 10:1, 16:1, 20:1, and 32:1 ratios. The pumps are made of stainless steel for use with these types of coating applications: solvents...
  • Page 28: Optional Equipment

    Refer to the Parts section to order these items. The following paragraphs describe the operation for the PMP 32/64 3. Theory of Operation Series pumps. Suction Stroke See Figure 2-2. Supply air enters the pump through the air valve (13) located on the air motor (2).
  • Page 29 4. Siphon ball and check valve 11. Piston 5. Siphon housing 12. Connecting tube 6. Pressure ball check valve 13. Air valve 7. Pressure housing 14. Muffler 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 30 Description Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 31 Section 3 Installation 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 32 Installation Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 33: General Pump Information

    Reduce ice buildup and exhaust noise by exhausting the air into a large, common pipe manifold. Use 76−102-mm (3−4-in.) diameter PVC pipe to fabricate a pipe manifold. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 34: Cavitation

    Keep the siphon strainer clean. Do not use a siphon strainer for high-viscosity materials. Use the largest and most practical ID siphon hose. Use the shortest and most practical siphon hose. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 35: Mounting Requirements

    4. Install the oiler (5) on the nipple. 5. Connect the elbow (6) to the oiler. 6. Install the regulator/oiler assembly on the pump (7). Tighten it securely. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 36 9.5-mm ( -in.) diameter and 305-mm (12-in.) long. The hose dampens vibrations. 9. Connect the air-supply hose to the air fitting (10). Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 37 6. Fluid filter drain valve 12. Air shut-off valve Note: Figure 3-2 illustrates the components in a typical system. Some of these components may not be in your system. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 38: D Manual

    Installation NOTE: Use only Nordson or equivalent PTFE hoses with electrical 4. Fluid Connections continuity between the fittings. Hoses must be capable of withstanding a maximum working pressure of 220 bar (3200 psi). Do not use pipe in a high-pressure circuit. As an alternative, use seamless steel tubing, 9.5-mm x 0.87-mm wall (...
  • Page 39 Section 4 Operation 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 40 Operation Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 41: Initial Startup

    8. To remove contaminants, allow the flush material to circulate through the system for a few minutes. If you are using a circulating system, keep the circulation valve (4) closed. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 42 2. Drain-off rod 6. Fluid filter drain valve 10. Air pressure regulator 3. Drain-off valve 7. Heater 11. Air lubricator 4. Circulation valve 8. Pump 12. Shut-off valve Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 43 8. If you are using a heater (7), turn it on. When the thermometer reads within 5_ of the desired operating temperature, adjust the circulation valve. The typical operating rate is 5−10 strokes per minute at rest (no spray devices triggered). 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 44 Flush all system components when the system is out of service for more than 24 hours or when using coating materials containing solids that settle out. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 45 Section 5 Maintenance 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 46 Maintenance Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 47: Solvent Chamber Fluids

    Install the drain plug. e. Fill the solvent chamber with fresh solvent chamber fluid. Use Nordson solvent chamber fluid. Refer to the Packing Gland and Solvent Chamber Fluid Guide in the Specifications section. Use the screws (1) to install the solvent chamber cover (2).
  • Page 48 Refer to the Parts section for the molybdenum disulfied part number. 4. Check the flow and level of vitalizer oil in the air lubricator. Use only Nordson vitalizer oil or its equivalent. 5. If they are used, drain the air filter/separator. Clean or replace the filter as necessary.
  • Page 49 Section 6 Troubleshooting 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 50 Troubleshooting Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 51 This section contains troubleshooting procedures. These procedures cover only the most common problems that you may encounter. If you cannot solve the problem with the information given here, contact your local Nordson representative for help. Problem Page Pump stops or fails to start...
  • Page 52 Ball check valve clogged or worn Perform the Changing Coating Materials inside the pump procedure, in the Operation section. If this does not solve problem, disassemble the hydraulic section and repair it. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 53 Stuck or clogged siphon ball check Remove ball check and clean or replace. Defective air motor or valve seals Check air valve and motor operation. Disassemble and replace seals if necessary. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 54 Material viscosity too high If possible, lower viscosity by adding pattern solvent or heat to material. Damaged nozzle or fluid tip Replace the nozzle or fluid tip. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 55 Section 7 Repair 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 56 Repair Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 57: Initial Startup

    Failure to observe this warning may result in serious injury. If maintenance requires complete pump disassembly, flush the system. Perform steps 1 through 8, Initial Startup, in the Operation section; then drain the system. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 58: How To Remove The Pump From Its Mount

    (9). 3. Remove the screws (12 and 15) securing the top cover plate (6) to the front cover plate (14). Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 59: Air Valve

    4. Muffler box lock washer 12. Screw 5. Muffler box 13. Air motor 6. Top cover plate 14. Front cover plate 7. Fillister head screw 15. Screw 8. Lock washer 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 60 3. Remove the screw (6), washer (7), lock washer (11) and nut (12) securing the snapper (8) and spacer (9) to the valve bracket (10). 4. Remove the fork (5), spring (4) and ball stem (3) from the snapper. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 61 3. Ball stem 11. Lock washer 4. Spring 12. Nut 5. Fork 13. Fillister head screws 6. Screw 14. Lock washer 7. Washer 15. Gasket 8. Snapper 16. Crankshaft 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 62 NOTE: The next step requires the use of a fillister head screw (Fig. 7-4, item 1). 2. Install a fillister head screw (2) through the crankshaft end bushing (3) and into the end of the crankshaft (9). Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 63 8. Center body 4. O-ring 9. Crankshaft 5. Crank shaft and end bushing 10. Arm O-ring Note: The fillister head screw (2) is only used for disassembly. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 64 3. Use the lock washers (2) and fillister head screws (1) to attach the left and right seal retainers to the center body. Tighten the screws securely. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 65 (5) to the air valve (9). Tighten the screws securely. 5. Use the screws (1) to install the muffler covers (2) on the muffler boxes (5). Tighten the screws securely. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 66: Air Motor

    4. See Figure 7-7. Remove the screws (6) and lock washers (5) securing the air motor (1) to the hydraulic section (3). 5. Pull the hydraulic section (3) away from the air motor to access the coupling (7). Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 67 7. Remove the air motor from the hydraulic section. 0112017A Fig. 7-7 Removing Air Motor 1. Air motor 5. Lock washer 2. Connecting rod 6. Screw 3. Hydraulic section 7. Coupling 4. Plunger 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 68: Piston Disassembly

    7. Use a wrench on the flats of the spool support (5) to remove the telescoping screw. 8. Remove the special nut (18), piston retaining nut (17), and O-ring (19) from the telescoping screw. Discard the O-ring. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 69: Cleaning And Inspecting Parts

    O-ring grease before installing the piston. 8. Install the piston assembly (22) into the cylinder (21). 9. Lightly coat the connecting rod (13) with vitalizer oil. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 70 18. Special nut 7. U-cup 19. O-ring 8. Cylinder head 20. O-ring 9. O-ring 21. Cylinder 10. Connecting tube 22. Piston assembly 11. Solvent chamber 23. U-cup 12. Coupling Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 71: 4:1 Hydraulic Section

    15. Test the pump. Refer to the Operation section for the procedures. The following paragraphs provide repair procedures for the 2/4:1 5. 2/4:1 Hydraulic Section Hydraulic Section. See Figure 7-9. Disassembly 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 72: Connecting Rod And Plunger Cap

    0112015A Fig. 7-9 Disconnecting the Plunger Rod 1. Solvent chamber cover 4. Plunger cap 2. Screw 5. Pump 3. Connecting rod 6. Coupling Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 73: Siphon Housing

    (2), and packing gland (1) from the solvent chamber (28). NOTE: The Type G packing gland (see Figure 7-12) does not have springs or washers. NOTE: Remove and replace the packing glands as an assembly. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 74: Plunger

    NOTE: The following step is not necessary for cleaning the pump. Perform this step to replace a worn or damaged plunger cap O-ring. 5. Remove the O-ring (23) from the plunger cap. Discard the O-ring. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 75 8. Screw 18. Backup washer 27. Studs 9. Lock washer 19. Piston cup 28. Solvent chamber 10. Ball retainer Note: Type-G packing gland also available. See Figure 8-7. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 76: Cleaning And Inspecting Parts

    Install the springs, washer (2) and packing gland (1) into the upper gland housing. NOTE: Type-G packing gland (see Figure 7-12) has no springs or washer. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 77: Siphon Housing

    (6) clockwise to connect the plunger cap and connecting rod. 2. Use the screws (2) to install the solvent chamber cover (1) to the pump (5). Tighten the screws securely. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 78: Installing The Packing Glands

    5. Shims (if used) 8. O-ring 3. V-rings 6. O-ring Type G Packing 0112033A Fig. 7-12 Type G Packings 1. Packing gland housing 3. Spacer 4. U-cup 2. O-ring Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 79: And 16/32:1 Hydraulic Sections

    7-23 Repair Repair procedures for the 10/20:1 and 16/32:1 hydraulic sections are 6. 10/20:1 and 16/32:1 provided in the following paragraphs. Hydraulic Sections Disassembly 1. See Figure 7-13. Remove the screws (3) securing the solvent chamber cover (2) to the pump (1).
  • Page 80 If the ball (17) and ball guide (16) remain in the lower housing (15), use needle-nose pliers to remove them. NOTE: The ball and seat wear into each other. Keep them together as a matched set. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 81 13. Lower packing (F or D) 20. Screw 7. Upper packing (F or D) 14. O-ring 21. Lock washer Note: Type-G packing gland available. See Figure 8-8. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 82: Cleaning And Inspecting Parts

    Place a wrench on the flats of the plunger. Screw the seat into the plunger. Tighten them securely. 6. Insert the plunger into the upper housing. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 83: Installing The Packing Glands

    12. Use the screws (3) to secure the solvent chamber cover (2) to the pump (1). Installing the Packing Glands Figures 7-15 and 7-16 illustrate how the packing glands are assembled. 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 84: Type D Or F Packing Glands

    Fig. 7-15 Type D or F Packings 1. Upper packing gland housing 3. Wave washers 5. Lower packing 2. Upper packing 4. O-ring 6. Lower packing gland housing Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 85: How To Install The Pump To Its Mount

    2. See Figure 7-1. Connect the hose to the siphon port (3). 3. Connect the hose to the fluid output port (2). 4. Connect the hose to the air intake fitting (1). 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 86 7-30 Repair Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 87 Section 8 Parts 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 88 Parts Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 89: Introduction

    Parts Section 8 Parts To order parts, call the Nordson Customer Service Center or your local 1. Introduction Nordson representative. Use this five-column parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list.
  • Page 90 159 488 S Plate, cover, front 981 016 S Screw, self tapping 981 098 S Screw, hex, with lockwasher, 8-32 x 0.375 in. 159 474 S Head, cylinder 940 164 S O-ring, Buna-N, 0.625 x 0.750 x 0.063 in. 159 467...
  • Page 91 S Washer, lock, split, #10 179 533 S Cover, solvent chamber 981 098 S Screw, hex, with lockwasher, 8-32 x 0.375 in. NOTE B: Refer to Air Valve in this section for ordering information. 106 588D Manual 1-12 E 1998 Nordson Corporation...
  • Page 92 Parts 2. Series-32 Air Motor Section (contd.) 0112011B Fig. 8-1 Series-32 Air Motor Section Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 93: Series-64 Air Motor Section

    159 488 S Plate, cover, front 981 016 S Screw, self tapping 981 098 S Screw, hex, with lockwasher, 8-32 x 0.375 in. 159 474 S Head, cylinder 940 164 S O-ring, Buna-N, 0.625 x 0.750 x 0.063 in 159 467...
  • Page 94 S Washer, lock, split, #10 179 533 S Cover, solvent chamber 981 098 S Screw, hex, with lockwasher, 8-32 x 0.375 in. 952 544 S Cup, U, 0.63 x 0.88 x 0.13 NOTE B: Refer to air valve parts list in this section.
  • Page 95 Parts 0112011B Fig. 8-2 Series-64 Air Motor Section 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 96: 2/4:1 Hydraulic Section

    B: Refer to Ball Check Service Kits in this section for ordering information. C: Included in packing gland and ball check kits. D: This ball is for standard coatings. Continued on next page Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 97 18 x 9 in., G8, zinc 983 150 S Washer, lock, steel, nickel 984 449 S Nut, hex, reg, -18, G8, zinc 0112012B Fig. 8-3 2/4:1 Hydraulic Section 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 98: Hydraulic Section

    S S Wave, spring 941 360 A, C S O-ring, Buna-N, 2.0 x 2.172 x 0.094 in. 178 449 S Housing, upper, hydraulic, 16/32:1 179 522 S Ring, clamp - - - - - - S Packing, lower 179 546...
  • Page 99 8-11 Parts 0112022A Fig. 8-4 10/20:1 Hydraulic Section 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 100: Hydraulic Section

    S S Wave, spring 941 360 A, C S O-ring, Buna-N, 2.0 x 2.172 x 0.094 in. 178 418 S Housing, upper, hydraulic, 16/32:1 178 421 S Ring, clamp - - - - - - S Packing, lower 140 895...
  • Page 101 8-13 Parts 0112022A Fig. 8-5 16/32:1 Hydraulic Section 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 102: Air Valve

    S Gasket, valve, air 246 468 S Arm 127 352 S Body, center 981 109 S Screw, socket head, #10-32 x 0.50, zinc, Nylok 323 012 S Bushing, end 941 080 S O-ring, Buna-N, 0.237 x 0.437 x 0.103 in. 940 154 S O-ring, Buna-N, 0.563 x 0.688 x 0.063 in.
  • Page 103 8-15 Parts 0112010A Fig. 8-6 Air Valve 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 104 941 101 S O-ring, Buna-N, 0.375 x 0.563 x 0.094 in. 942 440 S O-ring, hot paint, 4.25 x 4.5 x 0.125 in. 159 590 S Cylinder, air Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 105: 2/4:1 Hydraulic Section

    S O-ring, hot paint, 1.375 x 1.50 x 0.063 in. - - - - - - S Seat, ball, pressure 945 022 S O-ring, hot paint, OD tube 159 585 S Ball, 0.875 in., titanium nitride 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 106 8-18 Parts 16/32:1 Hydraulic Section See Figure 8-5. Item Part Description Quantity Note — 178 427 Service kit, ball check, stainless steel 178 425 S Ball, stainless steel, 0.500 in. dia 940 160 S O-ring, hot paint, 0.625 x 0.750 x 0.063 in.
  • Page 107: Hydraulic Section

    S O-ring, hot paint, 2.0 x 2.125 x 0.063 in. 900 025 S Ball, ceramic, 1.125 in., 100 940 260 S O-ring, hot paint, 1.250 x 1.375 x 0.063 in. 178 430 S Seat, siphon check 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 108 S O-ring, hot paint, 3.12 x 3.375 x 0.125 in. 246 217 S Cup, piston, 2:1 171 251 S Washer, energizing, cup 945 022 S O-ring, hot paint, tube Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 109 945 022 S O-ring, hot paint, tube 246 217 S Cup, piston, 2:1 171 251 S Washer, energizing, cup 159 586 S Spacer, U-cup, 2.76 x 2.132 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 110 8-22 Parts 2/4:1 Hydraulic Section (contd.) 0112031B Fig. 8-7 2/4:1 Hydraulic Section Packing Gland G Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 111: 16/32:1 Hydraulic Section

    Item Part Description Quantity Note — 178 422 Service kit, packing, 16/32:1, type D 940 160 S O-ring, hot paint, 0.625 x 0.750 x 0.063 in. 178 404 S Packing, upper 178 409 S S Spring, wave, 1 in. OD 941 360 S O-ring, Buna-N, 2.0 x 2.172 x 0.094 in.
  • Page 112 8-24 Parts 16/32:1 Hydraulic Section (contd.) See Figure 8-8. Item Part Description Quantity Note — 178 437 Service kit, packing, type G 940 160 S O-ring, hot paint, 0.625 x 0.750 x 0.063 in. 248 019 S Spacer, U-cup, upper 952 171 S S U-Cup, polyurethane, 0.812 x 1.312 in.
  • Page 113: 10/20:1 And 16/32:1 Hydraulic Section Packing Gland G

    8-25 Parts 10/20:1 and 16/32:1 Hydraulic Section Packing Gland G 0112030A Fig. 8-8 10/20:1 and 16/32:1 Hydraulic Section Packing Gland G 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 114: 10/20:1 Hydraulic Section

    S O-ring, Buna-N, 2.0 x 2.172 x 0.094 in. 940 330 S O-ring, hot paint, 2.0 x 2.125 x 0.063 in. 940 260 S O-ring, hot paint, 1.250 x 1.375 x 0.063 in. Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 115: Air Accessory Module

    S Oiler, 973 175 S Elbow, pipe, hyd, 90_, in., steel, zinc 973 053 S Nipple, extra heavy, x 3.00 in. 0112026A Fig. 8-9 Air Accessory Module 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 116: Siphon Accessory Module

    981 279 S S Screw, thumb, -20 x 1 in., stainless steel Î Î Î Î Î Î Î Î Î 0112023A Fig. 8-10 Siphon Accessory Module Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 117 Section 9 Specifications 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 118 Specifications Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 119: Technical Data

    177.8 mm (7 in.) Weight 88 kg (40 lb) Mounting Dimensions Mounting holes—9.5 mm (0.375 in.) diameter 149.25 x 84 mm (5.88 x 3.31 in.) on centers 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 120: Capacities

    @ 15 cycles (3.8 cfm) 4 bar (60 psig) Recommended 9.5 mm Minimum Air Line (0.375 in.) Size (ID) Fluid Outlet -in. NPT Connection Air Inlet Connection -in. NPT Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 121: Packing Gland And Solvent Chamber Fluid Guide

    NOTE A: Six hours or more of pot life. NOTE B: Less than six hours of pot life. NOTE C: Depends on application—Contact your Nordson representative. NOTE D: Some oils contain very strong solvents. Knowledge of contents is necessary before selecting packings.
  • Page 122: Air Consumption

    See to Figures 9-1 and 9-2. 3. Air Consumption PMP SERIES−32XX AIR CONSUMPTION STROKES PER MINUTE @ 30 PSI @ 60 PSI @ 90 PSI 0112028A Fig. 9-1 Series-32 Air Consumption Manual 1-12 106 588D E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 123 Specifications PMP SERIES−64XX AIR CONSUMPTION 19.8 STROKES PER MINUTE @ 30 PSI @ 60 PSI @ 90 PSI 0112029A Fig. 9-2 Series-64 Air Consumption 106 588D Manual 1-12 E 1998 Nordson Corporation All rights reserved Issued 8/98...
  • Page 124: Sound Level Summary

    Specifications Refer to Tables 9-3 and 9-4 for sound levels. 4. Sound Level Summary Table 9-3 Series-32 Pumps Air Pressure Sound Level (dB A) Sound Level (dB C) 4.13 bar (60 psi) 6.9 bar (100 psi) Table 9-4 Series-64 Pumps...
  • Page 125: Declaration Of Conformity

    DECLARATION of CONFORMITY PRODUCT: 32/64 Configurable Pumps (Air powered, demand, piston pump.) APPLICABLE DIRECTIVES: 89/392/EEC (Machinery) STANDARDS USED TO VERIFY COMPLIANCE: EN292 EN294 PRINCIPLES: This product has been manufactured according to good engineering practice. The product specified conforms to the directive and standards described above.

This manual is also suitable for:

64

Table of Contents