Power And Control; List Of Tables 4.1. Pin Assignment - RACOM RipEX User Manual

Radio modem & router
Hide thumbs Also See for RipEX:
Table of Contents

Advertisement

Warning – hazardous locations
Antenna has to be installed outside of the hazardous zone.
Fig. 4.7: Separated Rx and Tx antennas
Warning: RipEX radio modem may be damaged when operated without an antenna or a dummy load.

4.2.2. Power and Control

This rugged connector connects to a power supply and it contains control signals. A Plug with screw-
terminals and retaining screws for power and control connector is supplied with each RipEX. It is Tyco
7 pin terminal block plug, part No. 1776192-7, contact pitch 3.81 mm. The connector is designed for
electric wires with a cross section of 0.5 to 1.5 mm
cables should receive PKC 108 or less end sleeves before they are inserted in the clip. Insert the cables
in the wire ports, tightening securely.
Tab. 4.1: Pin assignment
pin
labeled
1
SI
2
AI
3
4
+
5
AO
6
+10–30VDC
7
−10–30VDC
Pins 3 and 7, 4 and 6 are connected internally.
© RACOM s.r.o. – RipEX Radio modem & Router
signal
SLEEP INPUT
HW ALARM INPUT
−(GND) – for SLEEP IN, HW ALARM INPUT
+(POWER) – for HW ALARM OUTPUT
HW ALARM OUTPUT
+POWER (10 to 30 V)
−POWER (GND)
2
. Strip the wire leads to 6 mm (1/4 inch). Isolated
Product