Gun Offset Adjustment; Tig Gas Control; Crater Delay - Lincoln Electric POWER FEED 25M Operator's Manual

Hide thumbs Also See for POWER FEED 25M:
Table of Contents

Advertisement

®
POWER FEED
25M & 25M ALUMINUM
Parameter
P.7

Gun Offset Adjustment

This option adjusts the wire feed speed calibration of the pull motor of a push-pull gun. This should
only be performed when other possible corrections do not solve any push-pull feeding problems. An
rpm meter is required to perform the pull gun motor offset calibration. To perform the calibration proce-
dure do the following:
1. Release the pressure arm on both the pull and push wire drives.
2. Set the wire feed speed to 200 ipm.
3. Remove wire from the pull wire drive.
4. Hold an rpm meter to the drive roll in the pull gun.
5. Pull the trigger on the push-pull gun.
6. Measure the rpm of the pull motor. The rpm should be between 115 and 125 rpm. If necessary,
decrease the calibration setting to slow the pull motor, or increase the calibration setting to speed up
the motor.
The calibration range is -30 to +120, with 90 as the default value.
Note: If a push/pull gun has been calibrated, an (*) will appear next to the calibrated value, indicating it
as such. If the user then manually adjusts the value, the (*) will remain on the calibrated value
for reference.
P.8

TIG Gas Control

This option allows control over which gas solenoid actuates while TIG welding.
"Valve (manual)" = No MIG solenoid will actuate while TIG welding, gas flow is manually controlled by
an external valve.
"Solenoid (auto) = This selection only applicable to PWC300. The MIG solenoid will turn on and off
automatically while TIG welding.
"Feeder Solenoid" = No applicable to PWC300. The internal (feeder) MIG solenoid will turn on and off
automatically while TIG welding.
"Pwr Src Solenoid" = Not applicable to PWC300. Any gas solenoid connected to the power source will
turn on and off automatically while TIG welding. This selection will not appear in the list if the power
source does not support a gas solenoid.
Notes: Preflow is not available while TIG welding. Postflow is available - the same postflow time will be
used in MIG and TIG. When machine output on/off is controlled via the upper right knob, gas
flow will not start until the tungsten touches the work. Gas flow will continue when the arc is
broken until the Postflow time expires. When machine output on/off is controlled via an arc start
switch or foot Amptrol, gas will begin flowing when the output is turned on and will continue
flowing until the output is turned off and the Postflow time expires.
P.9

Crater Delay

This option is used to skip the Crater sequence when making short tack welds. If the trigger is released
before the timer expires, Crater will be bypassed and the weld will end. If the trigger is released after
the timer expires, the Crater sequence will function normally (if enabled).
USER DEFINED PARAMETERS
Definition
B-24
OPERATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power feed 25m aluminiumPower feed 25m aluminum

Table of Contents