POWER FEED
25M & 25M ALUMINUM
If the passcode does not equal zero (0000), enter the passcode
now. If the passcode has been forgotten, a p.c. computer
application is required to change the passcode.
Memory Value
High Limit
200
HI = 200 LOW = 180
WELD WFS
WELD MODE
ARC CONTROL
Parameter Name
If the passcode has been set to zero (0000), SETUP will illuminate on
the user interface and the display will show the following:
Four items show on the user interface.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will change
when the user interface encoder is rotated. Press the right button
on the user interface to select the item to change.
200
HI = 200 LOW = 180
WELD WFS
WELD MODE
ARC CONTROL
Rotate to
Change
Value.
The Limits Setup menu shows a list of all parameters available
for the weld mode stored in the memory chosen. For example, if
limits are being set for a stick (SMAW) mode, parameters such
as Run-in WFS and Postflow will not appear.
To lock a parameter to a specific value that cannot be
changed, set the high and low limits to the same value.
Low Limit
SETUP
START OPTIONS
END OPTIONS
SET
SETUP
START OPTIONS
END OPTIONS
SET
Press to
select item
to change.
The memory value must always be less than or equal to the high
limit, and greater than or equal to the low limit.
After setting limits, press the memory button with the flashing
LED. The display will ask to save or discard the limit changes
just made. Press the left user interface for button (YES) to save
and enable the limits and exit. Press the right button (NO) to exit
and leave limits unchanged.

ENABLING/DISABLING LIMITS

Enable/Disable
Limits: Press
10 seconds
A
GUN B
1
5
Limits for each memory may be enabled or disabled by pressing
and hold the appropriate memory button for 10 seconds.
Release the memory button when the display shows the
following:
MEMORY 2 LIMITS
ENABLE/DISABLE
WELD MODE
ARC CONTROL
If the passcode does not equal zero, enter the passcode now. If the
passcode is zero (0000), SETUP will light and the displays the
following:
ENABLE
Yes
WELD MODE
ARC CONTROL
Press the left button (YES) to enable limits or the right button
(NO) to disable limits. Disabling limits does not change any
limits values that may have been previously set.
B-32
OPERATION
M
M
2
3
4
6
7
8
START OPTIONS
END OPTIONS
SET
LIMITS?
No
START OPTIONS
END OPTIONS
SET
SETUP
SETUP