Extension Bay; Connecting Up The Cables (Up To 16 Video Outputs) - Siemens SIMATRIX NEO V2 Configuration Manual

Table of Contents

Advertisement

8.2

Extension bay

8.2.1

Connecting up the cables (up to 16 video outputs)

Siemens AB
Security Products
The BNC cables required for cascade operation are not included in the standard supply!
The extension bay must be used with systems where more than 128 video inputs
are required. The extension bay allows expansion of the SIMATRIX NEO V2 to up
to a total of 224 or 240 video inputs in steps of 16 inputs, and up to a total of 32
video outputs in steps of 8 outputs.
Video outputs in the system
1 – 16
17 – 32
Fig. 24
Rear view of the extension bay
The extension bay features 16 video inputs, which are integrated into the
mainboard. The video input labels on the rear panel of the extension bay have
been designed for a system with a maximum of 16 video outputs.
Systems with more than 16 video outputs
A label sticker supplied with the extension bay can be used for systems with more
than 16 video outputs. This label sticker can be used to modify video output
numbering to suit this configuration, i.e. the video output number sequence starts
at 97 and ends at 224.
Connect the SysLink socket on the basic unit to the SysLink Input socket on
1.
the extension bay using the Syslink cable (identifiable by Syslink markings).
Unplug all the video input cables from video input 113 onward on the basic
2.
unit and plug them into the same input numbers on the extension bay.
Connect video outputs 1 to 16 on the extension bay to video outputs L1 to
3.
L16 (top row) on the basic unit.
Available video outputs
240
224
System extensions
39