Table of Contents

Advertisement

SIMATRIX NEO V2
Configuration Manual
Siemens AB
Security Products

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATRIX NEO V2

  • Page 1 SIMATRIX NEO V2 Configuration Manual Siemens AB Security Products...
  • Page 2 Contacting us If you have questions or suggestions regarding the product or this documentation, please contact our Technical Competence Center. E-mail: mailto:sp.support.de@siemens.com Tel.: +49 721 95 88088 (English) Internet: www.siemens.com/securityproducts Trainings Siemens provides training courses for all products.
  • Page 3: Table Of Contents

    5.6.2 Key allocation..................21     5.6.3 Indicator lamps..................21         Installation .....................22 SIMATRIX NEO V2 connections.............23     6.1.1 Interfaces and connections ..............23     6.1.2 Pin allocation for the 4-pin RJ9 telemetry port sockets......24     6.1.3 Pin allocation for the 6-pin RJ12 keyboard sockets........25...
  • Page 4 Extension up to a maximum of 32 video outputs (SIMNEO-SOM) ..41     Alarm box ....................42         Maintenance...................44     Disposal ....................45     Appendix ....................46 11.1 Glossary ....................46     11.2 Summary of basic and alarm program features........47     Siemens AB Security Products...
  • Page 5: Safety

    In this case the user is encouraged to perform appropriate measures to correct the interference. 1.2.2 Transport Damage during transport Keep the packaging material for future transportation.  Do not expose the device to mechanical vibrations or shocks.  Siemens AB Security Products...
  • Page 6: Setup

    Even after fuse failure dangerous voltages can still be present in the device. Use the device only in conjunction with a power supply cable that has been  approved in your country and complies with the national standards. Important information for Norway and Sweden: Siemens AB Security Products...
  • Page 7: Service And Maintenance

     performing maintenance. Danger of electrical shock while cleaning the device Disconnect the device from the mains supply before cleaning it.  Do not use liquid cleaners or sprays that contain alcohol, spirit or ammonia.  Siemens AB Security Products...
  • Page 8: Meaning Of The Written Warning Notices

    Possible danger of death or severe bodily harm CAUTION There is a risk of minor injuries or damage to property IMPORTANT Malfunctioning may result Meanings of the hazard symbols Warning Caution - Dangerous area! Warning Caution - Dangerous electrical voltage! Siemens AB Security Products...
  • Page 9: Directives And Standards

    This product complies with the requirements of the European Directives 2004/108/EEC “Directive of Electromagnetic Compatibility” and 2006/95/EEC “Low Voltage Directive”. The EU declaration of conformity is available to the responsible agencies at: Siemens AB Infrastructures & Cities Sector Security Products International Headquarters Englundavägen 7...
  • Page 10: Technical Data

    Protocols: CCDA, SCU, SIVIS, PELCO-D Connection: 4 x RJ11-Buchse / Port Sensor groups 32 x alarm inputs for detection groups Alarm sensors, alarm contacts Cable length: up to 10 m Connection: 2 x 37-pin Sub-D socket Siemens AB Security Products...
  • Page 11 8 output coupler PCB: 2.8 VA 5 to 45 C Operating temperature Relative humidity 30 to 85 %, non-condensing Construction 19 inch chassis, 6 HU Dimensions (w x h x d, chassis without 19”- 441 x 266 x 217 mm mount) Siemens AB Security Products...
  • Page 12: Ordering Information

    Weight designation (approx. In kg) 2GF2211-8AA SIMNEO-168 SIMATRIX NEO V2 168, complete, 19" base module, 6 HU, PAL model*, incl. CPU, 16 video inputs, 8 video outputs, 32 alarm inputs *Note: NTSC model available on request Extension options 2GF2211-8AB SIMNEO-EXT SIMATRIX NEO V2 19"...
  • Page 13: Total System With Full Options

    Total system with full options Total system with full options The SIMATRIX NEO V2 video matrix allows CCTV systems to be constructed in a compact, modular format. SIMATRIX NEO not only allows the connection of video signals using keyboards, it...
  • Page 14: Performance Characteristics

    Total system with full options Performance characteristics The SIMATRIX NEO V2 video matrix consists of a six standard height unit module (6HE), which contains both the system controls and the switching matrix. A maximum of 128 video input signals can be switched at will to a maximum of 32 video outputs (224 video input signals if the extension bay is used).
  • Page 15 – Management (IVM-NT) Control via freely programmable keyboards – Programming The following functions of the SIMATRIX NEO V2 are programmable: Time and weekday controlled alarm programs – Alarm group switching (max. 4 cameras) – Alarm and home positions of cameras with pan/tilt and lens controls –...
  • Page 16: Functional Description

    The SIMATRIX NEO V2 video matrix allows CCTV systems with video inputs and outputs to be constructed in a compact, modular format. The SIMATRIX NEO V2 switches video signals arriving at the video inputs in any user-defined combination to video monitors, image memories, video printers, etc., which are connected to the video outputs.
  • Page 17: Settings On The Cd-Rom

    The programs supplied cover the most common applications. They also make it easier to adjust programming to suit individual needs. The SIMATRIX NEO V2 is set to use alarm program 2 at the factory. The other alarm programs are described in the control software manual.
  • Page 18: Alarm Program 2 (Factory Setting)

    Each alarm requires manual acknowledgement. The most recent alarms are – acknowledged first. All the other alarms that have yet to be acknowledged are displayed as an alarm – image sequence on monitor 4 to allow gap-free video recording. Siemens AB Security Products...
  • Page 19: Interfaces

    Total system with full options Interfaces The central processor controls and administers the entire SIMATRIX NEO V2 system with all its video inputs and outputs, detector groups, switch outputs and interfaces to keyboards, CDCs or an external computer. The control profile depends on the way system parameters have been set (see the SIMATRIX NEO V2 programming manual).
  • Page 20: Peripheral Device Address Allocation

    Camera head drives, dome cameras and interfaces for camera programming must always be assigned an input. The SIMATRIX NEO V2 configuration software allows the allocation of other addresses. It is possible to select the same protocol for several telemetry ports of SIMATRIX NEO V2 and to assign an address several times.
  • Page 21: Key Allocation

    The indicator lamps (LEDs) on the front panel light up in the following colours to indicate system condition: yellow: immediately after switching on, as the system boots up – green: indicates a successful system start – Siemens AB Security Products...
  • Page 22: Installation

    Installation Installation The SIMATRIX NEO V2 system is built in modular 19 inch format. The 19 inch component trays have been designed to suit 19 inch frames and cabinets. The side walls of the component trays are perforated to allow good ventilation in the housing (via convection).
  • Page 23: Simatrix Neo V2 Connections

    Installation SIMATRIX NEO V2 connections Fig. 6 Rear view of the SIMATRIX NEO V2 (base module) 6.1.1 Interfaces and connections Interface Connection Telemetry port 1 Connections for dome cameras, 4 x RJ9, RS422 / RS485, Protocol: CDC (SCU) CCDA, CIVIS, Pelco-D, Molynx...
  • Page 24: Pin Allocation For The 4-Pin Rj9 Telemetry Port Sockets

    Contrary to SIMATRIX NEO where the protocol for each port was set at the factory, the SIMATRIX NEO V2 allows the free allocation of protocols to the ports. It is thus possible to use various protocols within one system or to set several ports to support the same protocol and thus to assign the same bus address several times.
  • Page 25: Pin Allocation For The 6-Pin Rj12 Keyboard Sockets

    200mA from the SIMATRIX NEO. The total current draw must not exceed 400mA. This means that the SIMATRIX NEO V2 can provide a current supply for a maximum of 4 SUT48s, CKA4810s or CKA3210s.
  • Page 26 Connecting an external computer to the COM interfaces on the NEO The following illustrations show how to connect a computer to the RS232 interface on the SIMATRIX NEO V2 (COM 2, COM 3, COM 4) using a 9-pin or 25-pin Sub-D connector: Fig.
  • Page 27: Pin Allocation For The 37-Pin Sub-D Alarm 1 - 16 And Alarm 17 - 32 Sockets

    Alarm input –TX TTY 8 Alarm input +TX TTY 8 Pin allocation for the Alarm 1 -16 37-pin Sub-D socket bar Tab. 4 Technical specifications and allocation identical to the alarm input modules of the SIMATRIX 648. Siemens AB Security Products...
  • Page 28: Connecting Camera Head Drives (Cdcs)

    Alarm input 30 +TX TTY 1 15 Alarm input 31 –TX TTY Alarm input 32 +TX TTY 1 16 Pin allocation for the Alarm 17 -32 37-pin Sub-D socket bar Tab. 5 6.1.5.1 Connecting camera head drives (CDCs) Siemens AB Security Products...
  • Page 29: Connecting The Tty/Ttl Interface Converter (Cac0101)

    Installation Fig. 12 Connecting camera head drives 6.1.5.2 Connecting the TTY/TTL interface converter (CAC0101) Fig. 13 Connecting interface converters (CAC0101) Siemens AB Security Products...
  • Page 30: Connecting The Converter For Dome Cameras (Cac0103)

    Installation 6.1.5.3 Connecting the converter for dome cameras (CAC0103) Fig. 14 Connecting interface converters (CAC0103) Siemens AB Security Products...
  • Page 31: 6.1.5.4 Connecting Alarm Sensors

    Installation 6.1.5.4 Connecting alarm sensors The SIMATRIX NEO V2 is able to process alarm sensors signals, which can be configured as normally closed or normally open contacts. The schematic below shows how to connect alarm sensor contacts: Fig. 15 Connecting a detection group to Alarm 1 - 16/ TTY out The detection group must be no further than 10 m distant from the SIMATRIX NEO.
  • Page 32: Pin Allocation For The 25-Pin Sub-D "Alarm Out" Socket

    Connection must then be made to the plus pole of the voltage supply to the relay. The cable connected to this socket must be no longer than 3 m. Relay switching example Fig. 18 Relay switching Siemens AB Security Products...
  • Page 33: Connecting The Video Inputs

    Connect video inputs to the BNC sockets that are labelled Video Input 1 Vss / 75 Ohm. Video sources that are compatible with the SIMATRIX NEO V2 provide a and an input impedance of 75 . PAL/CCIR video signal at a voltage of 1V Up to 16 video sources can be connected to the BNC sockets per input unit.
  • Page 34: Set-Up

    Connect the control PC to COM2 or COM4 using the null-modem cable. Or connect the NEO V2 to the PC using a switch / LAN crossover cable. Connect the SIMATRIX NEO V2 to the electrical supply 10. Switch on the SIMATRIX NEO; the device will now run through a self-test sequence.
  • Page 35: Installing The Control Software And Setting Device Parameters

    Use the CD supplied with the unit to install the control program. Then start up the control program. If the SIMATRIX NEO V2 is coupled via LAN and the IP address is not known, first use the diagnosis tool to find the SIMATRIX NEO V2 in the network, read out/assign the IP address, and then set the parameters via the network.
  • Page 36: Programming The Simatrix Neo

    Programming the SIMATRIX NEO The SIMATRIX NEO V2 is programmed at the factory to load alarm program 2 as standard. This program allows alarms to be received and processed immediately. The keyboards and the IVM- PCs will switch cameras in and out and control cameras with pan/tilt and lens drives.
  • Page 37: System Extensions

    This will provide extra reinforcement if the unit ever needs to be moved in the future. Finally, use the bus boards to connect all the video input modules and, if applicable, the blanking plate, to the mainboard. Siemens AB Security Products...
  • Page 38: Extension Up To A Maximum Of 32 Video Outputs (Simneo-Om)

    Each extra video output module must be inserted into the lowest available slot. Screw the module to the rear cover of the SIMATRIX NEO. Connect the module to the mainboard using a suitable flat cable. Fig. 23 SIMNEO-OM video output module Siemens AB Security Products...
  • Page 39: Extension Bay

    The extension bay must be used with systems where more than 128 video inputs are required. The extension bay allows expansion of the SIMATRIX NEO V2 to up to a total of 224 or 240 video inputs in steps of 16 inputs, and up to a total of 32 video outputs in steps of 8 outputs.
  • Page 40: Connecting Up The Cables (More Than 16 Video Outputs)

    224 – 240 209 – 224 Video input module address allocation on the extension bay Tab. 9 Each module must be inserted in the lowest available slot. Screw the module to the rear cover of the SIMATRIX NEO. Siemens AB Security Products...
  • Page 41: Extension Up To A Maximum Of 32 Video Outputs (Simneo-Som)

    Each extra video output module must be inserted into the lowest available slot. Screw the module to the rear cover of the SIMATRIX NEO Connect the module to the mainboard using a suitable flat cable. Fig. 26 SIMNEO-SOM video output module Siemens AB Security Products...
  • Page 42: Alarm Box

    System extensions Alarm box The alarm box extends the SIMATRIX NEO V2 by 128 alarm inputs. It is possible to operate two alarm boxes with a maximum of 240 alarm inputs. The way the alarm inputs are distributed over the basic unit, the extension bay and the alarm boxes is determined by an operating profile that is configured using the programming software.
  • Page 43 The alarm box SysLink interface has one input and one output and allows feed- through of the SysLink system to additional devices. SIMNEO-168 Basic unit SIMNEO-EXT Extension bay. When this unit is not used, the basic unit is connected directly to the first alarm box SIMNEO-A128 Alarm box Siemens AB Security Products...
  • Page 44: Maintenance

    The device must be isolated from the electrical supply before work starts on it. In the event of breakdown, we recommend you contact your local Siemens branch for service and support. The mains supply voltages and secondary voltages are fused as follows: Electrical supply 115 - 230 V AC (+10%/-15%), 50/60 Hz, 55 VA max.
  • Page 45: Disposal

    It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. Siemens AB Security Products...
  • Page 46: Appendix

    Dome cameras Ceiling-mounted, rapid-response, remote control camera with a lens drive system. Housed in a glass dome. CCDA Siemens dome cameras CCTV Closed Circuit Television, independent television system in a delimited area External detection group Group switching A key on the keyboard is used to switch the images from a camera group to a group of monitors.
  • Page 47: Summary Of Basic And Alarm Program Features

    4 images on monitor 4 alarm images on monitor 4 alarm images on monitor 4 Factory settings Deviation from the factory setting Siemens Building Technologies Fire Safety & Security Products 06.20013...
  • Page 48 Siemens AB Infrastructure & Cities Security Products International Headquarters Englundavägen 7 SE-171 24 Solna © 2013 Copyright by Siemens AB Tel. +46 8 629 0300 Data and design subject to change without notice. www.siemens.com/securityproducts Supply subject to availability. Document no.

Table of Contents