Installing The Control Software And Setting Device Parameters - Siemens SIMATRIX NEO V2 Configuration Manual

Table of Contents

Advertisement

7.2

Installing the control software and setting device parameters

Siemens AB
Security Products
Fig. 20
Second message following a system start (if keyboard 1 is connected)
T.1 =OK
This line means that keyboard 1 is connected.
2400 19.2k 19.2k 19.2k
This line indicates the data exchange rates for COM1 to COM4. In this example,
keyboard 1 communicates with the SIMATRIX NEO V2 at 2400 Baud. COM2,
COM3 and COM4 are set to 19,200 Baud.
Install the control software
1.
Use the CD supplied with the unit to install the control program. Then start up
the control program.
If the SIMATRIX NEO V2 is coupled via LAN and the IP address is not known,
2.
first use the diagnosis tool to find the SIMATRIX NEO V2 in the network, read
out/assign the IP address, and then set the parameters via the network.
Set the system time in the SIMATRIX NEO
3.
You must start the system's real-time clock if it is not active (No Time!
appears in the display),as otherwise a number of important system functions,
such as alarm sequencing, will not be available.
Control software: System real-time clock and OSD clocks button
Setting basic parameters
4.
Basic parameters button
Camera and monitor settings
Setting basic alarm parameters
5.
Basic alarm parameters button
Alarm sensor settings
Setting camera labels
6.
Camera texts button
Test cameras, monitors and keyboards
7.
Remote control and message receive button
Alarm sensor to camera allocation
8.
Alarm lines and camera groups button
Further programming
9.
If applicable, enter further parameters in order to tailor the function of the
Set-up
35