Quick Installation Guide
00825-0100-4648, Rev CC
February 2012
European Certifications
I1 ATEX Intrinsic Safety
Certificate No.: Baseefa07ATEX0011X
Ex ia IIC T5 (T
Ex ia IIC T4 (T
IP66/IP67
Special Conditions for Safe Use (X)
1. The antenna may present a potential electrostatic ignition hazard and must not be
rubbed or cleaned with a dry cloth.
2. The enclosure is made of an aluminum alloy and given a protective polyurethane
paint finish; however, care should be taken to protect it from impact or abrasion if
located in a zone 0 environment.
For use with Rosemount Power Module P/N 753-9220-0001 only.
Intrinsically Safe when installed per Rosemount drawing 00648-1020.
1180
Table 3. Sensor Parameters
Sensor
U
= 6.6 V
o
I
= 26 mA
o
P
= 42.6 mW
o
C
= 10.9 uF
o
L
= 500 mH
o
International Certifications
I7 IECEx Intrinsic Safety
Certificate No.: IECEx BAS 07.0007X
Ex ia IIC T6 (T
Ex ia IIC T5 (T
IP66/IP67
Special Conditions for Safe Use (X)
1. The antenna may present a potential electrostatic ignition hazard and must not be
rubbed or cleaned with a dry cloth.
2. The enclosure is made of an aluminum alloy and given a protective polyurethane
paint finish; however, care should be taken to protect it from impact or abrasion if
located in a zone 0 environment.
For use with Rosemount Power Module P/N 753-9220-0001 only.
Intrinsically Safe when installed per Rosemount drawing 00648-1020.
1180
= -60 °C to 40 °C)
a
= -60 °C to 70 °C)
a
= -60 °C to 50 °C)
amb
= -60 °C to 75 °C)
amb
Rosemount 648 Wireless
II 1G
13