Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 LNP-2804GN-SFP-T 28-Port Industrial Gigabit PoE+ Managed Ethernet Switches, with 24*10/100/1000Tx, and 4* Gigabit Combo Ports (4*10/100/1000Tx RJ45, 4*100/1000 SFP Slots); EOT: -40℃ to 75℃ Version 1.0 User Manual...
Page 2
Technologies, LLC may make improvements and/or changes to the product and/or specifications of the product described in this manual, without prior notice. Antaira Technologies, LLC will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual.
Industrial Grade Gigabit PoE Managed Ethernet Switches User Manual Version 1.0 (September 2017) This manual supports the following models: LNP-2804GN-SFP-T This document is the current official release manual. Please check our website (www.antaira.com) for any updated manual or contact us by e-mail (support@antaira.com).
SCADA systems or control networks. The LNP-2804GN-SFP-T is IP30 rated and rack mount design with extended temperature range (EOT: - 40°C to 75°C). It also provides high EFT and ESD protection for industrial networking applications, such as power/utility, water wastewater, oil/gas/mining, factory automation, security surveillance, ITS and any other outdoor or harsh environment applications.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 8k MAC address table Power Input DC 46~57V redundant with a 4-pin terminal block 2 alarm relay output Operating Temperature Extended operating temperature models: -40°C to 75°C ...
Industrial Gigabit PoE+ Managed Ethernet Switches with 24*10/100/1000Tx, and 4* Gigabit Combo Ports (4*10/100/1000Tx RJ45, 4*100/1000 SFP Slots). (W x D x H) is 438mm x 259.2mm x 43.6mm Figure 2.1 2.2 Front Panel The front panel of the LNP-2804GN-SFP-T series industrial gigabit PoE+ managed Ethernet switch is...
100/1000Fx Fiber Ports 10/100/1000Tx RJ45 Ports Figure 2.2 2.3 Back Panel Figure 2.3, below, shows the back panel of the LNP-2804GN-SFP-T switch that is equipped with one 4-pin terminal block connector for dual DC power inputs 46~57VDC. 3-pin terminal Console port...
Page 12
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 When loop detected, the LED is on. LOOP Detection No loop detected An active switch within the ring is a designated R. M. ring master Green (Ring Master) No ring master determined in current ring...
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 2.5 Reset Button There is a ‘Reset’ button located on the front panel of the industrial Ethernet switch that helps users to reboot or restore default by pressing the button for different seconds. Please refer to Table 2.2 for the timing and function.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) in length. 2.8 Wiring the Power Inputs There are two power inputs for normal and redundant power configurations. The power input 2 is used for wiring a redundant power configuration.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 2.9 Wiring a Relay Contact The following section details the wiring of the relay output. The wires are installed onto the fixed terminal block located on the back of the switch.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 3. Mounting Installation 3.1 Rack-Mounting Align the rack mount brackets with the holes on the switch. Secure the rack mount brackets with the provided screws. Align the switch with the posts on the rack cabinet.
Figure 4.1 4.2 Recommended Practices Antaira recommends creating a best practices policy for securing your network. This type of policy could be as simple as verifying that secure passwords have been used in place of default passwords but may also include other measures to maintain the security of the network.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 In the Password field, type in the new password. Re-type the same password in the Retype Password field. Click Apply to change the current account settings. Figure 4.2 After saving all the desired settings, perform a system save (Tools > Save Configuration). The changes are saved.
Page 19
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.3 The following table describes the items in Figure 4.3. Item Description System Name Click Switch to enter the system name: up to 128 alphanumeric characters (default is Switch).
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.6 Logging Message The Logging Message Filter page allows you to enable the display of the logging message filter. To access this page, click Monitoring > Logging Message. Figure 4.4 The following table describes the functions in Figure 4.4.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.7 Port Monitoring Port Network Monitor is a bandwidth and network monitoring tool for the purpose of capturing network traffic and measuring of network throughput. The monitoring functionality includes listing of port statistics as well as port utilization.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.6 The following table describes the functions in the previous figure. Function Description Refresh period Click the drop-down menu to select and designate a period (second intervals) to refresh the information (TX and RX) listings.
Page 23
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Function Description Clear Click Clear to reset LLDP Statistics of all the interfaces. Refresh Click Refresh to update the data on the screen with the present state of the data in the switch.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.10 IGMP/MLD Statistics The IGMP Statistics function displays statistical package information for IP multicasting. To access this page, click Monitoring > IGMP Statistics. Figure 4.8 Monitoring > IGMP Statistics The following table describes the function in Figure 4.8.
Page 25
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The MLD Statistics function displays statistical package information for IP multicasting. To access this page, click Monitoring > MLD Statistics. The following table describes the items in the previous figure.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.11 System 4.12 IP Settings The IP Settings menu allows you to select a static or DHCP network configuration. The Static displays the configurable settings for the static option. To access this page, click System > IP Settings.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for IP Address Information settings are informational only: DHCP State, Static IP Address, Static Subnet Mask, Static Gateway, Static DNS Server 1 and Static DNS Server 2.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for IPv6 Information settings are informational only: Auto Configuration, IPv6 In Use Address, IPv6 In Use Router, IPv6 Static Address, IPv6 Static Router and DHCPv6 Client. 4.14 DHCP Client Option 82 The DHCP Client Option 82 configurable Circuit ID and Remote ID feature enhances validation security by allowing you to select naming choices sub-options.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Mode Click the radio button to enable or disable the DHCP Client Option 82 mode. Circuit ID Format Click the drop-down menu to set the ID format: String, Hex, User Definition.
Page 30
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.12 System > DHCP Auto Provision The following table describes the items in the previous figure. Item Description Status Select the radio button to enable or disable the DHCP Auto Provisioning Setting.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.16 Management VLAN By default, the VLAN is the management VLAN providing communication with the switch management interface. To access this page, click System > Management VLAN. Figure 4.13 System > Management VLAN The following table describes the items in the previous figure.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.17 System Time To access this page, click System > System Time. Figure 4.14 System > System Time...
Page 33
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Enable SNTP Click the radio button to enable or disable the SNTP. SNTP/NTP Server Enter the address of the SNTP server. This is a text string of up to 64...
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.18 L2 Switching 4.19 Port Configuration Port Configuration describes how to use the user interface to configure LAN ports on the switch. To access this page, click L2 Switching > Port Configuration.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.20 Port Mirror Port mirroring function allows the sending of a copy of network packets seen on one switch port to a network monitoring connection on another switch port. Port mirroring can be used to analyze and debug data, diagnose errors on a network, or to mirror either inbound or outbound traffic (or both).
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Mirror Status settings are informational only: Session ID, Destination Port, Ingress State, Source TX Port and Source RX Port. 4.21 Link Aggregation Link Aggregation is a method for combining multiple network connections in parallel in order to increase throughput beyond the capability of a single connection, and to provide redundancy in case one of the links should fail.
Page 37
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.18 L2 Switching > Link Aggregation > LAG Management The following table describes the items in the previous figure. Item Description Click the drop-down menu to select the designated trunk group: Trunk 1 ~ 8.
Page 38
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.19 L2 Switching > Link Aggregation > LAG Port Settings The following table describes the items in the previous figure. Item Description LAG Select Click the drop-down menu to select a predefined LAG trunk definition: LAG 1-8.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description System Priority Enter the value (1-65535) to designate the LACP system priority. Apply Click Apply to save the values and update the screen.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for LACP Port Information settings are informational only: Port Name, Priority, Timeout, and Mode. 4.22 802.1Q VLAN The 802.1Q VLAN feature allows for a single VLAN to support multiple VLANs. With the 802.1Q feature you can preserve VLAN IDs and segregate different VLAN traffic.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for VLAN Table settings are informational only: VLAN ID, VLAN Name, VLAN Type, and Edit (click to enter VLAN name). PVID Settings The PVID Settings page allows you to designate a PVID for a selected port, define the accepted type, and enable/disable the ingress filtering.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Port VLAN Status settings are informational only: Port, Interface VLAN Mode, PVID, Accept Frame Type, and Ingress Filtering. Port to VLAN The Port to VLAN page allows you to add a port to a VLAN and select the related parameters.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Port Displays the assigned port to the entry. Interface VLAN Displays the assigned mode to the listed VLAN port.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.25 L2 Switching > Q-in-Q > Global Settings The following table describes the items in the previous figure. Item Description Outer VLAN Enter the outer VLAN handled by the switch giving the attached Ethertype machine a single-tagged 802.1Q VLAN frame.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Outer Mode Click the drop-down menu to select between UNI or NNI role. UNI: Selects a user-network interface which specifies communication between the specified user and a specified network.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Join Time Enter a value to specify the time between the transmission of GARP PDUs registering (or re-registering) membership for a VLAN or multicast group in centiseconds.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Status Click to enable or disable the GARP VLAN Registration Protocol administrative mode for the switch. The factory default is Disable.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.26 Multicast Multicast forwarding allows a single packet to be forwarded to multiple destinations. The service is based on an L2 switch receiving a single packet addressed to a specific Multicast address.
Page 49
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.31 L2 Switching > Multicast > IGMP Snooping > IGMP Settings The following table describes the items in the previous figure. Item Description IGMP Snooping Select Enable or Disable to designate the IGMP Snooping State.
Page 50
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.32 L2 Switching > Multicast > IGMP Snooping > IGMP Querier The following table describes the items in the previous figure. Item Description VLAN ID Select the VLAN ID to define the local IGMP querier.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for IGMP Static Groups Status settings are informational only: VLAN ID, Group IP Address, Member Ports, and Modify. Multicast Groups To access this page, click L2 Switching > Multicast > IGMP Snooping > Multicast Groups.
Page 52
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description MLD Snooping Select Enable or Disable to setup the MLD Snooping State. State MLD Snooping Select the querier version (V1 or V2) designated to the MLD Snooping...
Page 53
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description VLAN ID Enter the VLAN ID to configure. Querier State Select Enable or Disable status on the selected VLAN.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Multicast Groups To access this page, click L2 Switching > Multicast > MLD Snooping > Multicast Groups. The ensuing table for Multicast Groups settings are informational only: ID, Group IP Address, Member Ports, Type, and Life (Sec).
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.28 Spanning Tree The Spanning Tree Protocol (STP) is a network protocol to ensure loop-free topology for any bridged Ethernet local area network. STP Global Settings The STP Global Settings page allows you to set the STP status, select the configuration for a BPDU packet, choose the path overhead, force version, and set the configuration revision range.
Page 56
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 STP Port Settings The STP Port Settings page allows you to configure the ports for the setting, port’s contribution, configured edge port, and set the status of the BPDU filter.
Page 57
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for STP Port Status settings are informational only: Port, Admin Enable, Path Cost, Edge Port, and P2P MAC. STP Bridge Settings The STP Bridge Settings page allows you to configure the priority, forward delay, maximum age, Tx hold count, and the hello time for the bridge.
Page 58
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for STP Bridge Information settings are informational only: Priority, Forward Delay, Max Age, Tx Hold Count, and Hello Time. The ensuing table for STP Bridge Status settings are informational only: Bridge Identifier, Designated Root Bridge, Root Path Cost, Designated Bridge, Root Port, and Last Topology Change.
Page 59
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for STP Port Status settings are informational only: Port, Identifier (Priority / Port Id), Path Cost Conf/Oper, Designated Root Bridge, Root Path Cost, Designated Bridge, Edge Port Conf/Oper, P2P MAC Conf/Oper, Port Role, and Port State.
Page 60
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.43 L2 Switching > Spanning Tree > MST Instance ID Settings The following table describes the items in the previous figure. Item Description MSTI ID Enter the MST instance ID (0-15).
Page 61
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for MST Instance Priority Information settings are informational only: MSTI ID, Priority, and Action. MST Instance Info To access this page, click L2 Switching > Spanning Tree > MST Instance Info.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.29 X-Ring The X-Ring function provides an improvement over Spanning Tree and Rapid Spanning Tree and a rapid auto recovery in the event that the network suffers a corrupt or broken link and prevents network loops.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Ring ID Enter a number within the range of 1 to 255 to identify a given X-Ring group.
Page 64
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description State Select Enabled or Disabled to setup the loopback mode. Interval Enter the variable in seconds (1 to 32767) to set the interval at which frames are transmitted.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Loopback Detection Port Information settings are informational only: Port, Enable State, and Loop Status. 4.32 MAC Address Table The MAC Address Table provides access to the Static MAC Settings, MAC Aging Time, and Dynamic Forwarding.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Table 4-2. MAC Address Table > Static MAC Item Description MAC Address Enter the MAC address to which packets are statically forwarded.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.35 Dynamic Forwarding Table The Dynamic Forwarding function allows you to configure an address table, which contain the following: The port each hardware address is associated with The VLAN to show or clear dynamic MAC entries ...
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.36 Security The Security function allows for the configuration of Storm Control, Port Security, Protected Ports, DoS Prevention, Applications, 802.1x, and IP Security. 4.37 Storm Control The Storm Control page allows you to setup the units and Preamble/IFG to manage the occurrence of packet flooding on the LAN and consequent traffic to prevent the degrading of network performance.
Page 69
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.56 Security > Storm Control > Port Settings The following table describes the items in the previous figure. Item Description Port Enter the port number to designate the local port for the Storm Control function.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.38 Port Security The Port Security page allows you to configure port isolation behavior. To access this page, click Security > Port Security. Figure 4.57 Security > Port Security The following table describes the items in the previous figure.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.58 Security > Protected Ports The following table describes the items in the previous figure. Item Description Port List Enter the port number to designate for the Protected Port setting.
Page 72
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.59 Security > DoS Prevention > DoS Global Settings...
Page 73
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description DMAC = SMAC Click Enabled or Disabled to define DMAC-SMAC for the DoS Global settings. LAND Click Enabled or Disabled to define LAND for the DoS Global settings.
Page 74
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for DoS Global Information settings are informational only: DMAC = SMAC, Land Attack, UDP Blat, TCP Blat, POD (Ping of Death), IPv6 Min Fragment Size, ICMP Fragment Packets, IPv4 Ping Max Packet Size, IPv6 Ping Max Packet Size, Smurf Attack, TCP Min Header Length, TCP Syn (SPORT <...
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Port Select the port to configure for the DoS prevention function. DoS Protection Click Enabled or Disabled to set the DoS Port security function state.
Page 76
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Telnet Information settings are informational only: Telnet Service and Current Telnet Sessions Count. Secure Shell (SSH) is a protocol providing secure (encrypted) management connection to a remote device.
Page 77
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.63 Security > Applications > HTTP The following table describes the items in the previous figure. Item Description HTTP Service Click Enabled or Disabled to set up Ethernet encapsulation (remote access) through HTTP function.
Page 78
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description HTTPS Service Click Enabled or Disabled to set up Ethernet encapsulation over HTTPS. Session Timeout Enter the variable in minutes (0 to 86400) to define the timeout period for the HTTP session.
Page 79
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description State Click Enabled or Disabled to set up 802.1x Setting function. Server IP Enter the IP address of the local server providing authentication function.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Authentication Click Port or Mac to designate the type of configuration for the 802.1x based Port setting. Port Select Enter the port number associated with the configuration setting.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for IP Security Status settings are informational only: IP Security. Entry Settings Once the Global Setting is enabled, use the Entry Settings to define an IP Security entry.
Page 82
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 equal chance of being delivered in a timely manner. When there is congestion, all traffic has an equal chance of being dropped. The QoS feature can be configured for congestion-management and congestion-avoidance to specifically manage the priority of the traffic delivery.
Page 83
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.70 QoS > General > QoS Settings The following table describes the items in the previous figure. Item Description Port Enter the port number to associate with the QoS setting.
Page 84
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 the importance (weight) of the queue relative to the other CoS queues. WRR scheduling prevents low-priority queues from being completely ignored during periods of high priority traffic. The WRR scheduler sends some packets from each queue in turn.
Page 85
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 CoS Mapping The CoS Mapping allows you to apply CoS mapping. To access this page, click QoS > General > CoS Mapping. Figure 4.72 QoS > General > CoS Mapping The following table describes the items in the previous figure.
Page 86
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for CoS Mapping Information settings are informational only: CoS and Mapping to Queue. The ensuing table for Queue Mapping Information settings are informational only: Queue and Mapping to CoS.
Page 87
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.73 QoS > General > DSCP Mapping The following table describes the items in the previous figure. Item Description DSCP to Queue Mapping DSCP Enter the DSCP entry to define the precedence values.
Page 88
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Queue Mapping Information settings are informational only: Queue and Mapping to DSCP. IP Precedence Mapping The IP Precedence Mapping allows you to set IP Precedence mapping.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description IP Precedence to Queue Mapping IP Precedence Displays the IP precedence value for the queue map. Queue Click the drop-down menu to map a queue value to the selected IP precedence.
Page 90
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 To access this page, click QoS > QoS Basic Mode > Global Settings. The function is only available when QoS Properties is set to Basic. Figure 4.75 QoS > QoS Basic Mode > Global Settings The following table describes the items in the previous figure.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for QoS Port Status settings are informational only: Port and Trust State. 4.47 Rate Limit Rate Limit features control on a per port basis. Bandwidth control is supported for the following: Ingress Bandwidth Control, Egress Bandwidth Control, and Egress Queue.
Page 92
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Egress Bandwidth Control The Egress Bandwidth Control page allows you to set the egress bandwidth control for a listed port. To access this page, click QoS > Rate Limit > Egress Bandwidth Control.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.79 QoS > Rate Limit > Egress Queue The following table describes the items in the previous figure. Item Description Port Click the drop-down menu to select the port to define the Egress queue.
Page 94
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 To access this page, click Management > LLDP > LLDP System Settings. Figure 4.80 Management > LLDP > LLDP System Settings The following table describes the items in the previous figure.
Page 95
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 LLDP Port Settings The LLDP Port Settings page allows you to configure the state (enabled or disabled) of the selected port. To access this page, click Management > LLDP > LLDP Port Settings.
Page 96
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 802.3 Maximum Frame Size: To include maximum frame size TLV in LLDP frames. Management Address: To include management address TLV in LLDP frames. 802.1 PVID: To include port VLAN ID TLV in LLDP frames.
Page 97
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 To access this page, click Management > LLDP > LLDP Local Device Info. The ensuing table for Local Device Summary settings are informational only: Chassis ID Subtype, Chassis ID, System Name, System Description, Capabilities Supported, Capabilities Enabled, and Port ID Subtype.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 LLDP Overloading To access this page, click Management > LLDP > LLDP Overloading. The ensuing table for LLDP Overloading settings are informational only: Port, Total (Bytes), Left to Send (Bytes), Status, and Status (Mandatory TLVs, 802.3 TLVs, Optional TLVs and 802.1 TLVs).
Page 99
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 SNMP v1 and SNMP v2c use the group name (Community Name) certification. Its role is similar to the password function. If SNMP v1 and SNMP v2c are used, you can go directly from the configuration settings to this page to configure the SNMP community.
Page 100
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.87 Management > SNMP > SNMP User Settings The following table describes the items in the previous figure. Item Description User Name Enter a user name (up to 32 characters) to create an SNMP profile.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 SNMP Trap The SNMP Trap page allows you to set the IP address of the node and the SNMP credentials corresponding to the version that is included in the trap message.
Page 102
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 maximum available wattage. To access this page, click Management > Power Over Ethernet > PoE System Settings. Figure 4.89 Management > Power Over Ethernet > PoE System Settings The following table describes the items in the previous figure.
Page 103
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.90 Management > Power Over Ethernet > PoE Port Settings The following table describes the items in the previous figure. Item Description Port Click the drop-down menu to select a PoE port.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 PoE Port Status To access this page, click Management > Power Over Ethernet > PoE Port Status. The ensuing table for PoE Port Status settings are informational only: Port, Current (mA), Voltage (V), Power (W), and Temp.
Page 105
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Global Settings The Global Settings page allows you to configure the global settings for the DHCP function. To access this page, click Management > DHCP Server > Global Settings. Figure 4.93 Management > DHCP Server > Global Settings The following table describes the items in the previous figure.
Page 106
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Global Information settings are informational only: Lease Time, Low IP Address, High IP Address, Subnet Mask, Gateway, DNS, and Clear (click to clear IP pool). Port Settings The Port Settings page allows you to configure selected ports for the DHCP function.
Page 107
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Port Select Click the drop-down menu to select a pre-defined port to configure. The sub options are designated for the selected port.
Page 108
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Entry Click the drop-down menu to select a pre-defined entry to configure. VLAN ID Type in the value designating the ID (1 - 4094) Low IP Address Type in the value designating the highest range in the IP address pool.
Page 109
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.95 Management > DHCP Server > Option 82 Settings The following table describes the items in the previous figure. Item Description Entry Click the drop-down menu to select an entry for the Option 82 setting.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Entry Information settings are informational only: Entry (click the dropdown menu to select an entry), Entry ID, Circuit ID Format, Circuit ID Content, Remote ID Format, Remote ID Content, Low IP Address, High IP Address, Subnet Mask, Gateway, DNS, Edit (click to modify the settings), and Clear (click to clear the settings).
Page 111
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.96 Management > SMTP Client > Global Settings The following table describes the items in the previous figure. Item Description Active Profile Click the drop-down menu to select the profile status (None, 1 or 2).
Page 112
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Sender Mail Enter the email address of the sender client. Apply Click Apply to save the values and update the screen. Figure 4.98 Management > SMTP Client > Profile Settings > Profile Target Mail Settings The following table describes the items in the previous figure.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.99 Management > SMTP Client > Sending Message The following table describes the items in the previous figure. Item Description Title Assign the title of the email. The maximum length is 20 characters (alphanumeric, symbols, dots, underlines, dashes, and spaces).
Page 114
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.100 Management > RMON > Rmon Statistics The following table describes the items in the previous figure. Item Description Index Enter an entry selection (1 to 65535) to display its statistical information.
Page 115
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Index Enter the index entry (1 to 65535) to select the number of new history table entries. Port Select the specific port switch.
Page 116
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Index Enter the index entry (1 to 65535) to define a specific Alarm Collection history entry. Interval Enter a value (1 to 2147483647) to define the interval value for the Alarm Collection history.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Index Enter the index entry (1 to 65535) to define a specific RMON event. Description Enter a value (1 to 2147483647) to define the interval value for the Alarm Collection history.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Test Result settings are informational only: Port, Channel A, Cable Length A, Channel B, Cable Length B, Channel C, Cable Length C, Channel D and Cable Length D.
Page 119
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description IP Address Enter the IP address or host name of the station to ping. The initial value is blank. The IP Address or host name you enter is not retained across a power cycle.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.59 IPv6 Ping Test The IPv6 Ping Test page allows you to configure the Ping Test for IPv6. To access this page, click Diagnostics > IPv6 Ping Test. Figure 4.106 Diagnostics > IPv6 Ping Test...
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Item Description IPv6 Address Enter the IP address or host name of the station you want the switch to ping. The initial value is blank. The IP Address or host name you enter is not retained across a power cycle.
Page 122
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Logging Service Click Enabled or Disabled to set the Logging Service status. Apply Click Apply to save the values and update the screen.
Page 123
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Local Logging Settings Status settings are informational only: Status, Target, Severity, and Delete (click to delete the desired target). System Log Server The System Log Server page allows you to configure the log server.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The ensuing table for Remote Logging Setting Status settings are informational only: Status, Server Info, Severity, Facility and Delete (click to delete the desired server address). 4.61 DDM The DDM page allows you to setup the diagnostic alarm status.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.111 Diagnostics > DDM The following table describes the items in the previous figure. Item Description High Alarm Click Enabled or Disabled to set the alarm state. High Warning Click Enabled or Disabled to set the alarm state.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 The following table describes the items in the previous figure. Item Description Alarm is selected by default. State Click Enabled or Disabled to set the alarm state. Event Click Power Failure, Fiber Link down, or Port Link down to set the alarm event.
Backup Type Click a type to define the backup method: image, running configuration, startup configuration, flash log, or buffered log. Image Click the format for the image type: LNP-2804GN-SFP-T-x-xx-xx.hex (Active) or LNP-2804GN-SFP-T-x-xx-xx.hex (backup). Backup Click Backup to back up the settings.
Upgrade Type Click a type to define the upgrade method: image, startup configuration, or running configuration. Image Click the format for the image type: LNP-2804GN-SFP-T-x-xx-xx.hex (Active) or LNP-2804GN-SFP-T-x-xx-xx.hex (backup). Upgrade Click Upgrade to upgrade to the current version. 4.66 Dual Image The Dual Image page allows you to setup an active and backup partitions for firmware image redundancy.
LNP-2804GN-SFP-T User Manual V1.0 Item Description Active Image Click the format for the image type: LNP-2804GN-SFP-T-x-xx-xx.hex (Active) or LNP-2804GN-SFP-T-x-xx-xx.hex (backup). Save Click Save to save and keep the new settings. The ensuing table for Image Information 0/1 settings are informational only: Flash Partition, Image Name, Image Size and Created Time.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Figure 4.116 Tools > User Account The following table describes the items in the previous figure. Item Description User Name Enter the name of the new user entry. Password Type Click the drop-down menu to define the type of password: Clear Text, Encrypted, or No Password.
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 4.71 Reboot Device To access this page, click Tools > Reboot Device. Click Reboot to reboot the switch. Any configuration changes you have made since the last time you issued a save will be lost.
Page 132
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 Default Gateway: none User Name: admin Password: admin Follow the steps below to access the console via Telnet. Step 1: Telnet to the IP address of the switch from the Windows “Run” command as below.
Page 133
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 show system mac configure show system version firmware configure show system version loader configure admin username admin configure admin password admin configure boot host dhcp configure ip address [ip_addr] [ip_mask]...
Page 134
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 no name interface no shutdown interface show speed interface show duplex interface show flow control interface show name interface show link rx interface show link tx interface show link summary...
Page 135
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 show keepalive time interface show schedule [monday~sunday] enable interface show schedule [monday~sunday] start time interface show schedule [monday~sunday] end time interface spanning-tree mode [rstp | mst] configure spanning-tree priority [priority_value]...
Page 137
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 show event smtp warm-start configure show event smtp authentication-failure configure show event smtp interface [INTERFACE_NAME] up configure show event smtp interface [INTERFACE_NAME] down configure event syslog power1 enable configure event syslog power2 enable...
Page 138
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 syslog mode [all | remote | local | usb] configure no syslog server configure no syslog mode configure show syslog server configure show syslog mode configure show syslog log configure...
Page 139
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 snmp server v3 encryption [admin | user] [des | aes] [PWD] configure no snmp server enable configure no snmp server community [ro | rw] configure no snmp server v3 level [admin| user]...
Page 140
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 show snmp trap community configure show snmp trap inform retry configure show snmp trap inform timeout configure show snmp trap v3 user configure show snmp trap v3 level configure show snmp trap v3 engine-ID...
Page 142
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 no dhcp relay information option configure no dhcp relay information policy [replace | keep | drop] configure no dhcp relay untrust configure show dhcp service interface show dhcp server status...
Page 143
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 no dot1x authentication server 1 port configure no dot1x authentication server 1 share-key configure no dot1x authentication server 2 ip configure no dot1x authentication server 2 port configure no dot1x authentication server 2 share-key...
Page 144
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 tftp file name [UPGRADE_FILE_NAME] configure Save and Load Configuration File to/from USB CLI: enable configure terminal copy running-config usb (path) Fill in the folder and filename behind the “copy running-config usb” command.
Page 145
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 3. CLI: enable configure terminal copy usb startup-config (path) Fill in the folder and filename behind the “copy usb startup-config” command. Ex: file1, / folder /file2. Upgrade via TFTP CLI: enable ...
Antaira Technologies - Industrial Ethernet Switches LNP-2804GN-SFP-T User Manual V1.0 6. Technical Specifications Table 6.1 has the technical specifications. IEEE 802.3 10Base-T 10Mbit/s Ethernet IEEE 802.3u 100Base-Tx, 100Base-Fx, Fast Ethernet IEEE 802.3ab 1000Base-Tx Gigabit Ethernet IEEE 802.3z Gigabit Fiber IEEE 802.3x Flow Control for Full Duplex IEEE 802.3af...
Page 147
Antaira Customer Service and Support (Antaira US Headquarter) + 844-268-2472 (Antaira Europe Office) + 48-22-862-88-81 (Antaira Asia Office) + 886-2-2218-9733 Please report any problems to Antaira: www.antaira.com support@antaira.com www.antaira.eu info@antaira.eu www.antaira.com.tw info@antaira.com.tw Any changes to this material will be announced on the Antaira website.
Need help?
Do you have a question about the LNP-2804GN-SFP-T and is the answer not in the manual?
Questions and answers