3.6 M+FX5CCLIEF_StationNoSet

Description
Target module
CPU module
Engineering tool
Ladder diagram
81 steps
The number of FB steps integrated in the program varies depending on the CPU module used, the input/output definition, and
the setting options of GX Works3. For the setting options of GX Works3, refer to GX Works3 Operating Manual.
• When i_bEN (Execution command) is turned ON, the number is set to the station number specified with the set station
number.
• If an error occurs while setting the own station number, o_bErr (Error completion) turns ON, and the error code is stored in
o_uErrld (Error code). Refer to Page 44 Error code for details on the error codes.
Macro type
Pulsed execution (multiple scan execution type)
[For normal completion]
i_bEN
o_bENO
GP.UINI instruction Stop
o_bOK
o_bErr
o_uErrId
[For error completion]
(For instruction error)
i_bEN
o_bENO
GP.UINI instruction Stop
o_bOK
o_bErr
o_uErrId
• This FB does not include the error recovery processing. Program the error recovery processing separately in accordance
with the required system operation.
• This FB uses the GP.UINI instruction. The module parameter "Station Setting Method" must be set to "Set with Program" to
enable the GP.UINI instruction.
• Turn off i_bEN (Execution command) after o_bOK (Normal completion) or o_bErr (Error completion) is turned on. By turning
off i_bEN (Execution command), o_bOK (Normal completion) or o_bErr (Error completion) is turned off and o_uErrId (Error
code) is cleared to 0. However, because the GP.UINI instruction which is a pulse instruction in the FB is used, if a write is
performed while the FB is executed, the instruction may not be executed, and o_bOK (Normal completion) and o_bErr (Error
completion) may not turn on. If this happens, turn i_bEN (Execute command) from off to on again.
• This FB cannot be used in an interrupt program.
• Do not use this FB in programs that are executed only once, such as a subroutine program or FOR-NEXT loop, because
i_bEN (Execution command) cannot be turned off and the normal operation cannot be acquired. Always use this FB in
programs that can turn off i_bEN (Execution command).
• Every input must be provided with a value for proper FB operation.
• Set the module parameters in GX Works3 in accordance with the connected equipment and system. For the module
parameters, refer to the MELSEC iQ-F FX5 User's Manual (CC-Link IE).
Description
This error code is the same as the error code that occurs with the
own station number setting (GP.UINI) instruction.
FX5-CCLIEF
FX5U CPU, FX5UC CPU
GX Works3 Version 1.025B or later
Execution
0H
Execution
Stop
0H
Error code
Action
Refer to the MELSEC iQ-F FX5 User's Manual
(CC-Link IE)
Stop
0H