Chapter 7. SPECIAL MODULE COMMAND (BUFFER MEMORY READ/WRITE)

7.2 Remote Command

7.2.1 Buffer Memory Read- RGET

<Format>
Symbol
AB
Sl
upper lower
(8 bit) (8 bit)
EF
St
upper lower
(8 bit) (8 bit)
D
S
n
SS
REMARK
To read buffer memory data of A/D conversion module with RGET command, configure the
program so that execution condition of low(0) will be changed into high(1) at rising edge
(
<ex>
[configuration]
[Buffer memory read]
1) Read buffer memory address 39 to 54(16 Words) which A/D conversion value is stored.
2) Store read data to the next D0300
3) St o re information on the status of communication to D0001.
[Program]
RGET command execution condition
RGET command
execution condition
REGT
Descriptions
Upper(AB) : the code value of A/D Conversion module
G3F-AD4A: 00h, G3F-AD4B: 0Ah
G4F-AD2A: 80h
CD
Lower (CD): the slot number of communication module
of the master station.
Setting range: 0 to 7
Upper (EF): Slot number of A/D conversion module of
remote station.
Setting range: 0 to 31
GH
Lower(GH): communication module station number of
remote.
Setting range: 0 to 63
First address of device which stores read data.
First address of special module which will store read data.
Number of words of data read
Condition data display area of link
) . Or not, buffer memory data of A/D conversion module won't be read.
GM3- K7P-
G3I-
G3I- G3Q- G3Q-
PA2A 30AS
D24A D22A RY4A RY4A FUEA
[RGET h0A04 h010B D0300 00039 00016 D0001]
7 - 3
SI
St
D
S
n
SS
M, P, K, L, T, C, D, #D
M, P, K, L, T, C, D, #D
Slot 4
G3L-
Slot 1
GM3- G3L-
G3I -
G3F-
PA2A RBEA A24A AD4B
Remote Station No.11 (0Bh)
Device used
Integer
Integer
Integer
Integer, D