If a blank is installed in bay one, then install the Drive bay 1 airflow label (814814-001) as indicated.
Installing the Express Bay drive cage
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause ESD.
To install the component:
Back up all server data.
1.
Power down the server (on page 26).
2.
Do one of the following:
3.
Extend the server from the rack (on page 26).
o
Remove the server from the rack (on page 27).
o
Remove the access panel (on page 27).
4.
Remove the air baffle (on page 32).
5.
Remove the fan cage (on page 29).
6.
Hardware options installation 48