Press the Do Not Remove button to open the release handle.
2.
Install the drives.
3.
Install an SFF drive blank in any unused drive bays.
4.
6SFF NVMe Express Bay drive cage
The high-performance fan option (part number 719079-B21) must be installed when installing this option.
With the 6SFF NVMe Express bay Enablement option installed, the server supports SAS drives, SATA
drives, SSDs, and NVMe drives in the following locations:
•
Optional 2SFF drive cage installed either in Universal media bay 1 or at the rear of the server
supports SFF SAS drives, SATA drives, or SSDs.
•
8SFF drive cage (bays 1 to 8) installed in box 1 supports SFF SAS drives, SATA drives, or SSDs.
•
6SFF Express Bay Enablement option (bays 1 to 6) installed in Universal media bay 2 (box 2)
supports SFF NVMe drives.
For more information about NVMe SSDs, see the Hewlett Packard Enterprise website
(http://www.hpe.com/support/NVMedrive_en). For more information on supported drives, see the
Hewlett Packard Enterprise website (http://www.hpe.com/info/qs). For more information on which bays
support NVMe drives, see "Device numbers."
Hardware options installation 46