Group
Syntax
FUNCtion
Group
Syntax
Arguments
FCA3000, FCA3100, MCA3000 Series Programmer Manual
In remote mode (bus control), no consistency checks are made until you try to
issue an INITiate command. If, at that time, the settings are inconsistent, you get a
"Settings conflict" error, and the measurement will not start.
Sense
FREQuency:REGRession ON|OFF|AUTO
FREQuency:REGRession?
Selects which measuring function is to be performed and on which channel(s)
the instrument should measure.
Sense
FUNCtion '<Measuring function> [<Primary channel>
[,<Secondary channel>]]'
FUNCtion?
<MEASURING FUNCTION>
from the following table.
is the channel used in all single-channel measurements
<PRIMARY CHANNEL>
and the main channel in dual-channel measurements.
<SECONDARY CHANNEL>
Only the primary channel may be programmed for all single channel
measurements.
NOTE.
The measuring function and the channels together form one <String> that
must be placed within quotation marks.
Table 2-31: Measuring functions and channels
Measuring functions
FREQuency
FREQuency:RATio
FREQuency:BURSt
FREQuency:PRF
NCYCles
is the function you want to select. Choose a function
is the other channel in dual-channel measurements.
Available channels
1|2|3|4|6
1|2|3,1|2|3
1|2|3
1|2|3
1|2|3
Command Descriptions