Steps
16. Remove condenser and capillary
Remove the
condenser, unsolder the spot weld between
capillary
soldering, the refrigerant should be released
completely), pull it outward and then remove the
condenser and capillary
Remove gas valve and valve support
Remove the bolts used for fixing the gas valve
and valve support, and then remove the gas
valve;
Twist off the screws used for connecting the
valve support and chassis, pull it upward and
then remove the valve support
70
screws used for fixing the
and
condenser
(notice:
Procedure
before
Removal Procedure