Froling S3 Turbo Installation Instructions Manual page 22

Firewood boiler
Hide thumbs Also See for S3 Turbo:
Table of Contents

Advertisement

3
Test report data
S3 Turbo 40 - 45
22
Name
Test book number
Nominal output
Boiler class as per EN 303-5: 2012
Test data - Emissions in [mg/MJ]
Carbon monoxide (CO)
Nitrogen oxide (NOx)
Organic hydrocarbons (OGC)
Dust
Boiler efficiency (nominal load / partial
load)
1. The pollutant concentration is specified as a mass based on the energy content of the fuel fed to the combustion system in mg/MJ
Test data - Emissions in [mg/m³]
Carbon monoxide (CO)
Nitrogen oxide (NOx)
Organic hydrocarbons (OGC)
Dust
1. Emissions values based on dry flue gas at standard temperature and pressure (0°C, 1013 mbar) with a volume content of oxygen of 13%
Froeling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.at
S3 Turbo 40
PB0920016
kW
40
(nominal load / partial load)
1)
mg/MJ
47 / 296
mg/MJ
82 / 80
mg/MJ
2 / 12
mg/MJ
8 / 10
%
93.5 / 92.6
(nominal load / partial load)
1)
mg/m³
69 / 435
mg/m³
120 / 118
mg/m³
2 / 18
mg/m³
11 / 14
Technology
Technical specifications
S3 Turbo 45
PB0340011
45
5
55 / 190
85 / 86
2 / 7
9 / 10
94.1
81 / 280
125 / 127
3 / 11
14 / 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S3 Turbo and is the answer not in the manual?

Table of Contents