Technology
Technical specifications
S3 Turbo 30
Installation Instructions S3 Turbo | M1081217_en
Name
Nominal output
Electrical connection
Power consumption at nominal load
Power consumption in slumber mode
Weight of boiler incl. insulation and control
Total boiler capacity (water)
Water pressure drop (ΔT = 10 / 20 K)
Minimum boiler return temperature
Maximum permitted operating temperature
Permitted operating pressure
Airborne sound level
Permitted fuel as per EN ISO 17225
Fuel loading door dimensions (width / height)
Fuel loading chamber capacity
Combustion time
- beech
2)
Combustion time
- spruce
2)
1. S3 Turbo 30 with 31 kW nominal output only available in Austria and Italy
2. Values specified for combustion time are guideline values at nominal load and will vary depending on water content (15-25%) and fill level
(80-100%)
Energy efficiency
Rated heat output
Energy efficiency index of the boiler model
Seasonal space heating energy efficiency
Energy efficiency index of the boiler in package with
temperature control
Energy efficiency class of the boiler in package with
temperature control
kW
230V / 50Hz / fused C13A
W
kg
l
mbar
°C
bar
dB(A)
Part 5: Firewood class A2 / D15 L50
mm
l
h
Regulation (EU) 2015/1187
kW
%
S3 Turbo 30
S3 Turbo 30
30
31
51
49 - 70
3
530
120
6.1 / 2.0
60
90
3
< 70
330 / 370
140
3.9 - 5.6
2.8 - 3.9
A+
A+
30
31
117
115
80
78
119
117
A+
A+
3
1)
19
Need help?