Parameter list
Parameter
Name
54
FM terminal function selection
Frequency monitoring
55
reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
65
Retry selection
Stall prevention operation
66
reduction starting frequency
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Special regenerative brake
70
duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected
75
PU detection/PU stop
selection
77
Parameter write selection
Reverse rotation prevention
78
selection
 79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
Speed control gain (Advanced
89
magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
Motor constant (L1)/d-shaft
92
inductance
37
Setting
Initial
Parameter
Range
Value
1 to 3, 5,
7 to 12, 14,
1
21, 24, 52,
53, 61, 62
0 to 400Hz
60Hz
Inverter
0 to 500A
rated
current
0, 0.1 to 5s,
9999
9999
0 to 60s
1s
0, 1, 2, 3
0
0, 9
0
0 to 500A,
9999
9999
0 to 200%,
9999
9999
0 to 200%,
9999
9999
0 to 5
0
0 to 400Hz
60Hz
0 to 10,
0
101 to 110
0.1 to 360s
1s
0
0
0 to 30%
0%
0, 1, 3 to 6,
13 to 16, 23,
0
24, 40, 43,
44, 50, 53, 54
0 to 15
1
0, 1, 10, 11
1
0 to 8
1
0 to 3,
14
14 to 17
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4,
0
6, 7
0.1 to 15kW,
9999
9999
2, 4, 6, 8, 10,
9999
9999
0 to 500A
(0 to ****),
9999
9999

200/400V
0 to 1000V

10 to 120Hz
60Hz
0 to 200%,
9999
9999
0 to 50
(0 to ****),
9999
9999

0 to 50
(0 to ****),
9999
9999

0 to 1000mH
(0 to 50,
9999
0 to ****),
9999

Name
Motor constant (L2)/q-shaft
93
inductance
94
Motor constant (X)
96
Auto tuning setting/status
PU communication station
117
number
118
PU communication speed
PU communication stop bit
119
length
PU communication parity
120
check
Number of PU communication
121
retries
PU communication check time
122
interval
PU communication waiting
123
time setting
PU communication CR/LF
124
selection
Terminal 2 frequency setting
 125
gain frequency
Terminal 4 frequency setting
126
gain frequency
PID control automatic
127
switchover frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection 0 to 7
Built-in potentiometer
146

switching
Acceleration/deceleration time
147
switching frequency
150
Output current detection level 0 to 200%
Output current detection signal
151
delay time
152
Zero current detection level
153
Zero current detection time
Stall prevention operation
156
selection
157
OL signal output timer
 160
User group read selection
Frequency setting/key lock
161
operation selection
Automatic restart after
162
instantaneous power failure
selection
Stall prevention operation level
165
for restart
Setting
Initial
Range
Value
0 to 1000mH
(0 to 50,
9999
0 to ****),
9999

0 to 100%
(0 to 500,
9999
0 to ****),
9999

0, 1, 11, 21
0
0 to 31
0
(0 to 247)
48, 96, 192,
192
384
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0, 0.1 to
0
999.8s, 9999
0 to 150ms,
9999
9999
0, 1, 2
1
0 to 400Hz
60Hz
0 to 400Hz
60Hz
0 to 400Hz,
9999
9999
0, 20, 21,
40 to 43, 50,
0
51, 60, 61
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0.01 to
9999
10.00s, 9999
0
0, 1
1
0 to 400Hz,
9999
9999
150%
0 to 10s
0s
0 to 200%
5%
0 to 1s
0.5s
0 to 31, 100,
0
101
0 to 25s,
0s
9999
0, 1, 9999
0
0, 1, 10, 11
0
0, 1, 10, 11
1
0 to 200%
150%