Peripheral devices
2.1
Peripheral devices
Check the inverter model of the inverter you purchased. Appropriate peripheral devices must be selected according to the capacity.
Refer to the following list and prepare appropriate peripheral devices.
Applicable Inverter
Model
FR-E720-0.1K
FR-E720-0.2K
FR-E720-0.4K
FR-E720-0.75K
FR-E720-1.5K
FR-E720-2.2K
FR-E720-3.7K
FR-E720-5.5K
FR-E720-7.5K
FR-E720-11K
FR-E720-15K
FR-E740-0.4K
FR-E740-0.75K
FR-E740-1.5K
FR-E740-2.2K
FR-E740-3.7K
FR-E740-5.5K
FR-E740-7.5K
FR-E740-11K
FR-E740-15K
FR-E720S-0.1K
FR-E720S-0.2K
FR-E720S-0.4K
FR-E720S-0.75K
FR-E720S-1.5K
FR-E720S-2.2K

 Select an MCCB according to the power supply capacity.
 Install one MCCB per inverter.

For the use in the United States or Canada, refer to page 56, and select an appropriate fuse or molded case circuit
breaker (MCCB).

Magnetic contactor is selected based on the AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the magnetic contactor is
used for emergency stop during motor driving, the electrical durability is 25 times.
When using the MC for emergency stop during motor driving or using on the motor side during commercial-power supply operation, select the MC with class
AC-3 rated current for the motor rated current.

The power factor may be slightly lower.
NOTE
 When the inverter capacity is larger than the motor capacity, select an MCCB and a magnetic contactor according to
the inverter model and cable and reactor according to the motor output.
 When the breaker on the inverter input side trips, check for the wiring fault (short circuit), damage to internal parts of
the inverter, etc. Identify the cause of the trip, then remove the cause and power ON the breaker.
7
Molded Case Circuit Breaker
(MCCB)
Motor
or Earth Leakage Circuit Breaker
Output

(ELB)
(kW)
Reactor connection
without
0.1
5A
0.2
5A
0.4
5A
0.75
10A
1.5
15A
2.2
20A
3.7
30A
5.5
50A
7.5
60A
11
75A
15
125A
0.4
5A
0.75
5A
1.5
10A
2.2
15A
3.7
20A
5.5
30A
7.5
30A
11
50A
15
60A
0.1
5A
0.2
5A
0.4
10A
0.75
15A
1.5
20A
2.2
40A
Magnetic Contactor (MC)

(NF, NV type)
Reactor connection
with
without
5A
S-T10
5A
S-T10
5A
S-T10
10A
S-T10
15A
S-T10
15A
S-T10
30A
S-T21
40A
S-T35
50A
S-T35
75A
S-T35
100A
S-T50
5A
S-T10
5A
S-T10
10A
S-T10
10A
S-T10
15A
S-T10
20A
S-T21
30A
S-T21
40A
S-T21
50A
S-T35
5A
S-T10
5A
S-T10
10A
S-T10
10A
S-T10
20A
S-T10
30A
S-T21
Reactor

FR-HAL
with
S-T10
0.4K

S-T10
0.4K
S-T10
0.4K
S-T10
0.75K
S-T10
1.5K
S-T10
2.2K
S-T10
3.7K
S-T21
5.5K
S-T35
7.5K
S-T35
11K
S-T50
15K
S-T10
H0.4K
S-T10
H0.75K
S-T10
H1.5K
S-T10
H2.2K
S-T10
H3.7K
S-T12
H5.5K
S-T21
H7.5K
S-T21
H11K
S-T21
H15K

S-T10
0.4K

S-T10
0.4K

S-T10
0.75K

S-T10
1.5K

S-T10
2.2K

S-T10
3.7K
MCCB
MCCB
FR-HEL

0.4K

0.4K
0.4K
0.75K
1.5K
2.2K
3.7K
5.5K
7.5K
11K
15K
H0.4K
H0.75K
H1.5K
H2.2K
H3.7K
H5.5K
H7.5K
H11K
H15K

0.4K

0.4K

0.75K

1.5K

2.2K

3.7K
INV
IM
INV
IM