7.4. Measuring resistance, capacitance,
continuity and diode test
WARNING
Serious risk of injury to the user and/or destruction of the instrument
during resistance testing.
> Test object must be de-energized.
External voltages will distort the measurement result.

7.4.1. testo 770-1/-2

Manual measuring mode
1.
Switch instrument on: set rotary switch to
-
The instrument is switched on.
2.
Connect test leads: black test lead to black jack, red test lead to red
jack. Then connect test leads to the test object.
-
The instrument is in
3.
Switch between resistance, capacitance, continuity and diode test:
press
[
-
The measured value is shown on the LC display.

7.4.2. testo 770-3

Automatic measuring mode
Automatic detection for resistance/capacitance in the following
range:
0.0 ohms to 6.000 mohms
0.500 nF to 600.0 µF
Change to manual measuring mode for the remaining measuring
range.
1.
Switch instrument on: set rotary switch to
-
The instrument is switched on.
2.
Connect test leads: black test lead to black jack, red test lead to red
jack. Then connect test leads to the test object.
-
The instrument is in
-
The instrument detects resistance, continuity, diode and capacitance
and automatically adjusts the measuring range.
-
The measured value is shown on the LC display.
Manual measuring mode
3.
Disable
AUTO RCDC
4.
Switch between resistance, capacitance, continuity and diode test:
press
[
-
The measured value is shown on the LC display.
>
Switch back to
measuring mode.
]
<1 s.
AUTO RCDC
measuring mode: press
]
<1 s.
AUTO
mode: press
7 Carrying out a measurement
.
.
measuring mode.
[
[
]
>2 s.
]
<1 s.
15