EXCELL PRECISION CO., LTD. Table of Content INSTRUCTION FOR USE ....................2 PREPARING TO USE THE SCALE ..................2 CHAPTER 1 INTRODUCTION .................... 3 1-1 F ..................3 EATURES AND PECIFICATIONS 1-2 P ......................3 OWER UPPLY 1-3 P ................4...
EXCELL PRECISION CO., LTD. Thank you for purchasing EXCELL waterproof weighing scale. In order to use the scale properly, please read this instruction carefully before use. If you have a problem concerning the scale, please contact your supplier. Instruction for Use 1.
Surrounded by waterproof grade sheeting to ensure the water free. 1/3,000~1/6,000 display resolution available. ESW Max adopts stainless steel housing while ELW Max and plastic ABS housing. High speed of 24bits AD fast reacts and shortens the weighing operation duration.
EXCELL PRECISION CO., LTD. Low Battery Warning When shows up, it will have approximately 10 hours of operation left. Then symbol will flash on the display; please replace the dry batteries soon when one of those two symbols appears. When the battery voltage is less than 3.8 V, the scale would power off automatically.
EXCELL PRECISION CO., LTD. UNITS KEY Press the UNITS key to switch weight units; the icons will indicate the active units. NET/GROSS KEY In the Tare mode, the screen displays the “TARE” icon; press the NET/GROSS key to switch between the “Net value” and the “Gross value”.
EXCELL PRECISION CO., LTD. SIMPLE COUNTING FUNCTION (1) Use the UNITS key to enter into the “PCS” mode (2) Press the NET/GROSS key to select the counting sample size (S = 10, S = 20, S = 50, S = 100, S=200).
EXCELL PRECISION CO., LTD. INTERNAL VALUE MODE (must hook up Load Cell to test) Press to enter, and the display shows internal value TARE Please check whether the internal value has changed obviously with weight changing. Please check the backlight.
EXCELL PRECISION CO., LTD. Chapter 2 Advanced Functions 2-1 Advanced Function Setting Table Below is an overview of the advanced functions. For detailed settings refer to the following sections: DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED...
EXCELL PRECISION CO., LTD. 2-2 Advanced Function Setting Workflow In the weighing mode, press the keys at the same time to NET/GROSS ON/ZERO enter the Advanced Function setting mode. The LCD shows Overall workflow of the Advanced Function setting mode:...
EXCELL PRECISION CO., LTD. 2-3 General Function Setting Workflow of the General Function setting: DISPLAY NOTE ACTIONS Press TARE ON/ZERO key Upward key (from 0 to 9) UNITS key Downward key (from 9 to 0) TARE key Move the cursor to right Use the keys to select NET/GROSS key ...
EXCELL PRECISION CO., LTD. 2-3-1 Automatic Backlight Function Setting Select in the General Function setting mode to change the backlight function setting. NOTE ACTIONS DISPLAY Press TARE LCD displays the last saved status ON/ZERO UNITS key to select function “on” or “off...
EXCELL PRECISION CO., LTD. 2-3-2 Automatic Power-off Timer Setting Select in the General Function setting mode to change the automatic power-off timer setting. DISPLAY NOTE ACTIONS Press TARE key LCD displays the last saved status Use ON/ZERO or UNITS key...
EXCELL PRECISION CO., LTD. 2-3-3 Hi/Lo/OK Function Setting Select in the General Function setting mode to set the Hi/Lo/OK function. This function is available in all unit modes. In one specific unit mode, enter to set the Hi/Lo/OK values. When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled.
EXCELL PRECISION CO., LTD. 2-3-4 Restore to the Default Setting Select in the General Function setting mode to restore to the default setting. DISPLAY NOTE ACTIONS Return (Cancel the Press TARE key restoration) Restore to the default Use ON/ZERO or UNITS keys setting to select “return”...
EXCELL PRECISION CO., LTD. 2-3-5 Noise Filter Setting Select in the General Function setting mode to set the noise filter setting. When modifying , the parameters of remain un-altered. NOTE DISPLAY ACTIONS Returning to zero point setting LCD displays the last saved status...
EXCELL PRECISION CO., LTD. 2-3-6 Hold Function Setting Select in the General Function setting mode to set the hold function. ACTIONS NOTE DISPLAY Press TARE key Hold function setting LCD displays the last saved parameter setting Hold function setting Use ON/ZERO or UNITS key...
EXCELL PRECISION CO., LTD. 2-3-7 Auto Unit Weight Averaging Setting Select in the General Function setting mode to set Auto Unit Weight Averaging. ACTIONS NOTE DISPLAY Press TARE key Auto unit weight averaging setting LCD displays the last saved parameter...
EXCELL PRECISION CO., LTD. 2-3-8 Two Weighing Units Setting Select in the General Function setting mode to set the two weighing units Setting. Two weighing units setting LCD displays the last saved parameter setting Press Two weighing units setting TARE...
EXCELL PRECISION CO., LTD. 2-3-9 Unstable Tare Unstable Tare setting LCD displays the last saved parameter setting Press TARE Unstable Tare setting key to key in the ON|ZERO UNITS parameters for second weighing unit Default setting = 0 0 Disable tare operation while unstable...
EXCELL PRECISION CO., LTD. 2-4 Weight Calibration In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows and use the NET/GROSS or UNITS key to select to enter the weight calibration mode.
EXCELL PRECISION CO., LTD. Appendix 1 Command Mode &Output data format only work with models have WIFI card or BLE card installed inside Command Mode Command Format A Host Command Slave Command Zero Switch to the first weighing unit...
Page 24
EXCELL PRECISION CO., LTD. Note : (Weighing unit) is various depended on models 00 The first weighing unit WS00HI001000<CR><LF> Write HIGH values WS00HI001000<CR><LF> ANS: Command Format D Host Data Slave Value (e.g. Price) Position of decimal point When the Slave receives this data format, it will transfer the data and display it on its LCD.