EXCELL PRECISION CO., LTD. Table of Content INSTRUCTION FOR USE ....................2 PREPARING TO USE THE SCALE ..................2 CHAPTER 1 INTRODUCTION ....................4 1-1 F ..................4 EATURES AND PECIFICATIONS 1-2 P ......................4 OWER UPPLY 1-3 P ................5 ANEL AND EYBOARD NTRODUCTION 1-4 O ....................5...
EXCELL PRECISION CO., LTD. Thank you for purchasing EXCELL waterproof weighing scale. In order to use the scale properly, please read this instruction carefully before use. If you have a problem concerning the scale, please contact your supplier. Instruction for Use 1.
Page 5
EXCELL PRECISION CO., LTD. Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours.
EXCELL PRECISION CO., LTD. Chapter 1 Introduction 1-1 Features and Specifications Features: Sealed waterproof silica gel strip blocks water from infiltrating into the scale. Surrounded by waterproof grade sheeting to ensure the water free. 1/3,000~1/6,000 display resolution available. Aluminum frames coated with anti-corrosion treatment for longer lifespan.
EXCELL PRECISION CO., LTD. 1-3 Panel and Keyboard Introduction Icon Introduction STABLE : The weight is stable. GROSS : The scale is in the gross mode. The display shows the goods and any container weight. This Gross status indication is on when the TARE function is used.
Page 8
EXCELL PRECISION CO., LTD. ZERO When the weigh pan is empty (free of load) and the display is not showing zero, press the ON/ZERO key to zero the scale. At zero, the “ 0 ” indication is on. When the weight value is within the zero range, the zero function operates to zero the scale or cancel the tare function.
EXCELL PRECISION CO., LTD. To power off in this mode, the scale will memorize the “Pcs” unit. When the scale is powered on again, it directly enters the simple counting mode. While the “Auto unit weight average” function is available in the Advanced Function, the goods on the weigh pan are 5pcs greater than the sample size and less than double the sample size, the scale will automatically re-sample the unit weight.
EXCELL PRECISION CO., LTD. 1-6 Error Messages ⇒ Initial zero is higher than the zero range when switching the indicator on. (Approval models) ⇒ Initial zero is lower than the zero range when switching the indicator on. (Approval models) ⇒...
EXCELL PRECISION CO., LTD. Chapter 2 Advanced Functions 2-1 Advanced Function Setting Table Below is an overview of the advanced functions. For detailed settings refer to the following sections: DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED...
EXCELL PRECISION CO., LTD. 2-2 Advanced Function Setting Workflow In the weighing mode, press the keys at the same time to NET/GROSS ON/ZERO enter the Advanced Function setting mode. The LCD shows Overall workflow of the Advanced Function setting mode:...
EXCELL PRECISION CO., LTD. 2-3 General Function Setting There are 7 functions in the general function setting mode from Workflow of the General Function setting: DISPLAY NOTE ACTIONS Press TARE ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒...
EXCELL PRECISION CO., LTD. 2-3-1 Automatic Backlight Function Setting Select in the General Function setting mode to change the backlight function setting. NOTE ACTIONS DISPLAY Press TARE LCD displays the last status ON/ZERO UNITS key to select function “on” or “off...
EXCELL PRECISION CO., LTD. 2-3-2 Automatic Power-off Timer Setting Select in the General Function setting mode to change the automatic power-off timer setting. DISPLAY NOTE ACTIONS Press TARE key LCD displays the last status Use ON/ZERO or UNITS key Automatic power-off timer setting...
EXCELL PRECISION CO., LTD. 2-3-3 Hi/Lo/OK Function Setting Select in the General Function setting mode to set the Hi/Lo/OK function. This function is available in all unit modes. In one specific unit mode, enter to set the Hi/Lo/OK values. When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled.
EXCELL PRECISION CO., LTD. 2-3-4 Restore to the Default Setting Select in the General Function setting mode to restore to the default setting. DISPLAY NOTE ACTIONS ⇒ Return (Cancel the Press TARE key restoration) ⇒ Restore to the default Use ON/ZERO or UNITS keys setting to select “return”...
EXCELL PRECISION CO., LTD. 2-3-5 Noise Filter Setting Select in the General Function setting mode to set the noise filter setting. When modifying , the parameters of remain un-altered. NOTE DISPLAY ACTIONS Returning to zero point setting LCD displays the last status...
EXCELL PRECISION CO., LTD. 2-3-6 Hold Function Setting Select in the General Function setting mode to set the hold function. ACTIONS NOTE DISPLAY Press TARE key Hold function setting LCD displays the last parameter setting Hold function setting Use ON/ZERO or UNITS key...
EXCELL PRECISION CO., LTD. 2-3-7 Auto Unit Weight Averaging Setting Select in the General Function setting mode to set Auto Unit Weight Averaging. ACTIONS NOTE DISPLAY Press TARE key Auto unit weight averaging setting LCD displays the last parameter setting...
EXCELL PRECISION CO., LTD. 2-4 Weight Calibration In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows and use the NET/GROSS or UNITS key to select to enter the weight calibration mode.