Precautions for Safe Use

1. When unpacking the Units, check carefully for any external scratches or other damage.
2. The PT must be installed in a control panel.
3. The mounting panel must be between 1.6 and 4.8 mm thick. Tighten the Mounting
4. Do not let metal particles enter the Units when preparing the panel.
5. Do not connect an AC power supply to the DC power terminals.
6. Do not perform a dielectric voltage test.
7. Use a DC power supply that will provide a stable output even if the input is momentarily
8. Use a twisted-pair cable to connect to the power terminals. Tighten the terminal screws
9. To prevent malfunctions caused by noise, ground the PT correctly.
10. Do not touch the surface of the circuit boards or the components mounted on them with
11. Turn OFF the power supply before connecting or disconnecting cables.
12. The maximum tensile load for cables is 30 N. Do not apply loads greater than this.
13. Confirm the safety of the system before turning ON or OFF the power supply.
14. Cycle the power supply after changing the DIP switch settings.
15. Do not perform the following operations while the SD memory card is being accessed
• Turning OFF the power supply to the PT
• Removing the memory card
16. Start actual system application only after sufficiently checking screen data and the op-
17. Do not press the touch switch with a force greater than 30 N.
18. Do not use a screwdriver or any other tool to press a touch switch.
19. Confirm the safety of the system before pressing any touch switch.
20. Do not accidentally press touch switches when the backlight is not lit or when the dis-
Also, shake the Units gently and check for any abnormal sound.
Brackets evenly to a torque of between 0.1 and 0.25 N·m for the NV3W/NV3Q and be-
tween 0.2 and 0.3 N·m for the NV3W-V1/NV4W to maintain water and dust resistance.
Make sure the panel is not dirty or warped and that it is strong enough to hold the Units.
interrupted for 10 ms, and which has reinforced or double insulation.
Model
NV3W-M@20L
5 VDC (allowable range: 4.5 to 5.5 VDC)
NV3W-M@20L-V1
NV4W-M@21
24 VDC (allowable range: 21.6 to 26.4 VDC) 1.7 W min.
NV4W-M@41
NV3W-M@20
NV3W-M@40
NV3W-M@20-V1
NV3W-M@40-V1
NV3Q-MR@@
NV3Q-SW@@
to a torque of between 0.22 and 0.30 N·m. Make sure the screws are properly tight-
ened.
your bare hands. Discharge any static electricity from your body before handling the
boards.
(NV4W and NV3Q only):
Always follow the specified procedure when removing the memory card.
eration of the program in the PLC (host).
play does not appear. Confirm the safety of the system before pressing touch switches.
Rated power supply voltage
Capacity
1 W min.
2 W min.
1.9 W min.
2.4 W min.
3.6 W min.
xv