Page 1
Programmable Terminal NA-series Practices Guide HMI Remote Viewer For the Elementary Level NA5-15[]101[] NA5-12[]101[] NA5-9[]001[] NA5-7[]001[] V430-E1-01...
Page 2
■ Introduction This guide provides reference information when using HMI Remote Viewer. It does not provide safety information. Be sure to obtain the NA-series Programmable Terminal User's Manuals, read and understand the safety points and other information required for use, and test sufficiently before actually using the equipment.
Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied.
It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
1 Related Manuals The following manuals are related to this manual. Cat.No. Model Manual Name W501 NX701-[][][][] NJ/NX-series CPU Unit Software NJ501-[][][][] User’s Manual NJ301-[][][][] NJ101-[][][][] W506 NX701-[][][][] NJ/NX-series CPU Unit Built-in EtherNet/IP Port NJ501-[][][][] User’s Manual NJ301-[][][][] NJ101-[][][][] W504 SYSMAC-SE2[][][] Sysmac Studio Version 1 Operation Manual W502...
Copyrigh hts and Trad demarks Sysmac c and SYSM MAC are trad demarks or r registered tr rademarks o of OMRON Corpora ation in Japa an and othe r countries f for OMRON factory auto omation pro ducts. Screens...
3 erview w of t the H MI Re emot e Vie ewer The HMI R Remote View wer is an app plication tha at provides a a remote ope eration by co onnecting the NA-ser ries to a tab let with VNC C (Virtual Ne etwork Comp...
4 Descri iption of the HMI R Remote e View wer Scr reen his section d describes ea ach screen o of the HMI R Remote View wer. 4-1 Initia al Screen he following shows the i initial screen n after starti ng the HMI Remote Vie ewer.
4-2 S Setup Scre The follow ing screen c can set the d device to be e connected. Name escription A thum Thum mbnail mbnail shows t the screen whe en VNC was di isconnected to the NA. A Sys smac logo is di splayed if no c onnection has...
4-3 Disp play and Operatio n Screen he following screen can display and d operate the e NA screen (3) (4) (5 Name Descr iption Displays a Operation n screen a screen of the e connected NA You can o operate it from the tablet.
5 line o of Set tting Proc cedur Perform th he following procedures starting from m “installing the HMI Re emote Viewe er to an iPad d” until “conn ecting VNC to the NA”. Setting IP Address of t the NJ Setting IP Address of t he NA...
Page 14
6 Settin ng IP ress of th e NJ erform the fo ollowing pro ocedure to se et an IP add dress of the Select [Multiview Explore er]->[Configu urations and Setup]- ->[Controller Setup]- ->[Built-in Et therNet/IP Po Setting gs] on the NJ J project, and double -click (or righ...
Page 15
7 Sett ting I P Ad dress s of t he NA Perform th he following procedure to o set an IP a address of t he NA. Sele ect [Multiview plorer]->[Con nfigurations a Setu up]->[HMI Se ettings] on th he NA proj ject, and dou...
8 Setting g VNC for th e NA he VNC serv ver function must be en abled to pub blish the dis play screen of the NA. ow to enable e the VNC s server functi on is given below. ou can make e the setting g from HMI S...
8-2 S Setting fro om the De evice Sys stem Men nu of the rform the foll lowing proce edure to ena ables the VN NC function on the Devic c e System M Menu during operation o of the NA. Star rt the NA and d select “Dev...
Page 18
Sele ect either of “ “View Only” “Vie ew and Opera ate” from the “Mo ode” pull-dow wn menu. Sele ect “Change Password”, set a w password ( 5 to 8 alphan numeric racters long) ), and click th “App ply”...
Ethe ernet commu unications. rform the fol lowing proce edure to con nnect the NA A-series with h an iPad us s ing OMRON “WE E70-AP”. nnect the WE E70-AP to a pers sonal compu uter with an E...
Page 20
Clic ck “Wireless s settings” to o open. ”08CH(2447 7 MHz)” to “Ch annel”, and click the ”Ap ply” butt ton. Clic ck “Advanced d settings” to o open. “Invalid” to “ “ANY- conne ection fusal”, set “In nvalid” to ”11 prot tection functi ion”, and clic...
1 0 etwo ork Se etting g for i iPad To connec ct an iPad to the NA usin ng the HMI R Remote View wer with VN N C connectio on, network of iPad mu ust be set. Perform th he following procedure to o set netwo...
11 1 Inst talling a and St tarting the HM MI Rem mote Vie ewer erform the fo ollowing pro ocedure start ting from “st tarting the H HMI Remote Viewer” unt “c connecting th he NA-serie s with VNC connection”...
Starting the HMI Remote Viewer 11-2 To s start the HM I Remote Vie ewer, touc ch ”HMI View wer” added o on the me screen aft ter installatio on of the I Remote Vie ewer. the initial sc creen of HMI Remote e Viewer.
Page 24
Ente er the passw word that you u set for VNC setting gs of the NA, touc ch”OK”. A sc creen of the NA is display yed on iPad. Make sure that the e screen is o perational. To e exit the VNC C connection, touc...
1 2 Operat ting t the H HMI Re emot te Vie ewer This sectio on describes s how to ope erate the HM MI Remote V Viewer that is s connected d to the NA-series during VNC C connection Tap Ope eration 12-1...
Page 26
Long t Durin ng a long tap p, the tapped d momentar r y button is b being Press a and hold sur rface with press sed down. fingerti This is the equivale ent operation n to pressin ng and holdin ng down the screen This ge...
Drag Op peration 12-2 Dragging i s a gesture to move fing gertip over t the surface w without losin ng contact w while the object is be eing presse d and held d down. The follow ing explains s a drag ope eration durin g the VNC c connection.
12-3 F lick Oper ration icking is a g gesture to qu uickly brush surface with h fingertip. he following explains a f flick operatio on during th e VNC conn n ection. Touch the screen a and quickly b rush surface e with fingert...
Pinch in n/Pinch ou ut Operat tion 12-4 Pinching is a gesture to t touch surfac ce with two f fingers and b bring them c closer or wid der together. The following g explains th he pinch in/p pinch out op erations dur ring the VNC C connection...
12-5 D Deleting th he Regist tered Scr reen he following explains ho ow to delete the screen registered w w ith the HMI Remote Vie e wer. Touch ”Remove” o n the setup screen A pop u up is display yed.
Need help?
Do you have a question about the NA Series and is the answer not in the manual?
Questions and answers