Sf6 Gas Detection Mode Menu; Gas Detection Conditions - Fluke Ti200 User Manual

Thermal imagers
Hide thumbs Also See for Ti200:
Table of Contents

Advertisement

SF6 Gas Detection Mode Menu

The Imager can operate in radiometric mode or in gas detection mode. The Imager cannot
operate in both modes at the same time. When SF6 Gas Detection Mode is enabled, the
radiometric features of the Imager are disabled and cannot be selected in the menus.
Table 16 lists the options in the SF6 Gas Detection Mode menu.
Option
SF6 Gas Detection
Mode: ON
SF6 Gas Detection
Mode: OFF
Image Capture
Video Capture
High Gain (Tripod)
Low Gain (Handheld)

Gas Detection Conditions

The Imager detects gas leaks based on:
The temperature difference between the gas and the background environment
The wind speed
The amount of clutter in the background scene (for example, clouds)
The stability of the Imager
The proximity of the Imager to the leak
The lower the volume of the gas leak the more challenging it is for the Imager to detect the leak.
To improve the gas detection rate, place the Imager where:
The temperature difference between the gas and the background environment is the greatest.
There is a light wind.
There is limited clutter in the background scene. A clear blue sky is optimal.
The Imager is stable. When possible, use a tripod and High Gain (Tripod) mode.
The Imager is close to the leak. If close proximity is not possible, use the 2X lens.
Note
Table 16. SF6 Gas Detection Mode Menu
Turns on the gas detection mode. See Gas Detection Conditions.
Turns off the gas detection mode.
Sets up the Imager to capture an image in gas mode when SF6 Gas
Detection Mode: ON is enabled.
Sets up the Imager to capture a video in gas mode when SF6 Gas
Detection Mode: ON is enabled.
Optimizes the sensitivity of the display when the Imager is mounted on a
tripod when SF6 Gas Detection Mode: ON is enabled. See Gas
Detection Conditions.
Optimizes the sensitivity of the display when the Imager is held in a hand
when SF6 Gas Detection Mode: ON is enabled. See Gas Detection
Conditions.
Note
Description
Thermal Imagers
Menus
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ti300Ti450sf6Ti480Ti400Ti450

Table of Contents