Foreword
Caution
SIMODRIVE and SIMOVERT MASTERDRIVES drive units with synchronous motors are
subject, as part of the type test, to a voltage test corresponding to EN 50178. According to
EN 60204-1, Section 19.4, while electrical equipment of industrial machines are being
subject to a voltage test, all of the SIMODRIVE and SIMOVERT MASTERDRIVES drive unit
connections must be disconnected/withdrawn in order to avoid damaging the SIMODRIVE
and SIMOVERT MASTERDRIVES drive units.
Motors should be connected-up according to the circuit diagram provided. They must not be
connected directly to the three-phase supply because this will damage them.
Note
SIMODRIVE and SIMOVERT MASTERDRIVES drive units with synchronous motors fulfill,
when operational and in dry equipment rooms, the Low-Voltage Directive 73/23/EEC.
SIMODRIVE and SIMOVERT MASTERDRIVES drive units with synchronous motors fulfill, in
the configurations specified in the associated EC Declaration of Conformity, EMC Directive
89/336/EEC.
vi
Configuration Manual, (PJAL), 11.2005 Edition, 6SN1 197-0AD07-0BP4
General Section for Synchronous Motors