Siemens SIMODRIVE 611 Configuration Manual page 59

Low-voltage converter, general section for synchronous motors
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

Figure 5-4
Table 5-2
component
F
K1
R2
Figure 5-5
Important information and instructions when installing the connecting cable
The brake connecting cable is included in the power cable. The insulation between the
power and brake connection is dimensioned for the basic insulation (VDE 600 V/1000V UL).
The relay K1, located between the coil and contact, must also have basic insulation in order
to protect the internal logic voltage (PELV=Protective Extra Low Voltage). The PELV supply
may not be used to supply the holding brake (refer to the Fig. "Recommended circuit for the
external power supply with protective circuit").
General Section for Synchronous Motors
Configuration Manual, (PJAL), 11.2005 Edition, 6SN1 197-0AD07-0BP4
Recommended circuit for the external power supply with protective circuit
Example: Electronic components for the recommended circuit
Electr.
3RV10 circuit-breaker with current
paths connected in series. (if
required with mounted auxiliary
contact 3RV1901 to provide a
feedback signal for the drive)
Auxiliary contactor 3RH11
Varistor
SIOVS14K30 (EPCOS)
Terminology (time) for holding operation
Examples
or
Miniature circuit-breaker
5SX21. (if required with mounted
auxiliary contact to provide a feedback
signal for the drive)
or
Contactor 3RT10
Motor Components
5.4 Holding brake
5-9