Dynamic Dosing Restrictor Selection Graphs
Use the graphs on pages 62- 66 as a guide to determine
the correct restrictor size for your desired flow and mate-
rial viscosity. Table 6 lists the available restrictor sizes.
Example:
Application: air spray system with a 5:1 mix ratio
Fluid Supply: 1:1 pumps at 100 psi (7 bar, 0.7 MPa)
Flow Rate: 300 cc/min at the gun
Select the Restrictor Size: choose either the 0.040
or 0.070 orifice, to ensure that the pressure differen-
tial is not more than 10-20 psi (0.7-1.4 bar,
0.07-0.14 MPa), provided the fluid viscosities are
similar to those tested.
•
If the viscosity of component B is lower than the vis-
cosity of the chart used for selection you may need
to use a smaller restrictor or decrease the pressure
differential.
•
If the viscosity of component B is higher than the
viscosity of the chart used for selection you may
need to use a larger restrictor or increase the pres-
sure differential.
•
In systems using an air-assisted gun, if the fluid
pressure of component A is higher than the compo-
nent A pressure from the charts you may need to
use a larger restrictor or increase the pressure dif-
ferential.
3A0869C
Dynamic Dosing Restrictor Selection Graphs
Table 6: Restrictor Sizes
Size Code
Orifice Size
2*
3*
4*
5✓
6✓
7*
8✓
*
These restrictors are included in Injection Kit
15U955.
✓ These restrictors are optional sizes, not included in
the Injection Kit.
Part No.
0.020
15U936
0.030
15U937
0.040
15U938
0.050
15U939
0.060
15U940
0.070
15U941
0.080
16D554