Setup Mode Details
Calibration 1 and 2 (Screens 22
and 23)
NOTE: See Meter Calibration, page 32, for detailed
instructions.
Calibration 1 (Screen 22) displays if
Setup Home (Screen 17). This screen displays the k fac-
tor (cc/pulse) for Meter A with fluid A1 (A2 and A3, if
present) and Meter B. The system starts at the default
factor(s) for the meters. Factor values update automati-
cally as needed based on calibration results from Cali-
bration 2 (Screen 23). Factor values also can be set on
this screen, from 0 to 0.873 cc/pulse.
F
. 43. Calibration 1 (Screen 22)
IG
Press
to display Calibration 2 (Screen 23). This
screen allows the user to perform a calibration. It dis-
plays Meter A (with fluid A1, A2, and A3) and Meter B
k-factors, the target dispense volume, the actual dis-
pense volume (settable from 0 to 9999 cc), and the
material to dispense.
Meter B
Meter A
k factor
k factors
Cancel Meter
Start Meter A
Calibration
or Meter B
Calibration
F
. 44. Calibration 2 (Screen 23)
IG
46
is selected on
Meter k
factors
Home
Selected
material
Active
Recipe
Target
dispense
volume
Actual
dispense
volume
Home
Press
to highlight the meter you wish to cali-
brate. Press
. An X displays in the box.
Press
to start the calibration on the checked
meter (A with fluid A1, A2, or A3, or B). Press
to cancel the calibration.
Press
to highlight the actual dispense vol-
ume field. Press
9999 cc). Press
Press
to change a digit. Press
field is correct.
Use
to toggle between Calibration 1
(Screen 22) and Calibration 2 (Screen 23).

Troubleshooting (Screens 35-37)

Screens for testing system controls can be accessed by
setting the password to 9909. See Configure 3 (Screen
20), page 43, to set or change the password.
After setting the password to 9909, press
Setup. Press
to reenter Setup. Setup Home
(Screen 17) displays, with troubleshooting screen
options.
Troubleshooting
screen options
appear here.
F
. 45. Setup Home with Troubleshooting
IG
to set the volume (from 0 to
to move between digits.
when
to exit
3A0869C