Ranges For User Inputs - Graco ProMix 2KE Operation

Meter-based plural component proportioner
Hide thumbs Also See for ProMix 2KE:
Table of Contents

Advertisement

Display Module

Ranges for User Inputs

This table is a one-sheet reference of the data range accepted for each user input. See the page indicated in the
table for further screen information, if needed.
Page
Screen
40
Run Mix Batch (3)
42
Password (16)
43
Configure 1 (18)
43
Configure 1 (18)
43
Configure 1 (18)
43
Configure 1 (18)
43
Configure 1 (18)
43
Configure 2 (19)
43
Configure 2 (19)
43
Configure 3 (20)
43
Configure 3 (20)
43
Configure 3 (20)
43
Configure 3 (20)
43
Configure 3 (20)
43
Configure 3 (20)
43
Configure 4 (21)
43
Configure 4 (21)
44
Recipe 1-1 (28)
Recipe 2-1 (30)
Recipe 3-1 (32)
44
Recipe 1-1 (28)
Recipe 2-1 (30)
Recipe 3-1 (32)
44
Recipe 1-1 (28)
Recipe 2-1 (30)
Recipe 3-1 (32)
44
Recipe 0 (27)
Recipe 1-2 (29)
Recipe 2-2 (31)
Recipe 3-2 (33)
45
Maintenance 1 (24)
45
Maintenance 1 (24)
45
Maintenance 2 (25)
45
Maintenance 3 (26)
46
Calibration 1 (22)
46
Calibration 2 (23)
26
User Input
Target Volume
Password
System Type
Dosing Type
Gun Flush Box Enable
Number of Guns
Number of Colors
Gun 1 or Gun 2 hose length
Gun 1 or Gun 2 hose diameter
USB Log Language
Date Format
Date
Time
Password
Backlight Timer
Distance Units
Volume Units
Ratio
Ratio Tolerance
Potlife Timer
Flush Times - First (A purge),
Second (B purge), or Third
(using A or B, selected by user)
Meter A or Meter B
Solvent Valve A or B
Dose Valve A1, A2, A3, or B
Fluid Filter A or B, or Air Filter
Meter A1, A2, A3, or B K-Factor
Actual Dispensed Volume
Range/Options
1 to 9999 cc
0000 to 9999
Meters; 50cc Pump; 75cc Pump; 100cc
Pump; 125cc Pump; 150cc Pump
Dynamic (A
50cc Sequential (A-B 50cc)
100cc Sequential (A-B 100cc)
On or Off
1 or 2 guns
1 or 3 colors
0.1 to 45.7 m / 0.3 to 150 ft
0.1 to 1 inch
Chinese; Dutch; English; French; German;
Italian; Japanese; Korean; Portuguese;
Russian; Spanish; Swedish;
mm/dd/yy; dd/mm/yy; yy/mm/dd
01/01/00 to 12/31/99
00:00 to 23:59
0000 to 9999
0 to 99 minutes
Feet/inches or Meters/cm
Liters; Gallons US; Gallons Imperial
0:1 to 30:1
Note: Enter 0 to dispense A only.
1 to 99 percent
0 to 240 minutes
Note: If set to 0, potlife alarm is
disabled.
0 to 240 seconds
Note: If set to 0, the valve(s) will not flush.
0 to 2,000,000 L / 0 to 528,344 gal
0 to 9,999,999
0 to 9,999,999
0 to 9999 days
0 to 0.873 cc/pulse
0 to 9999 cc
Default
0 cc
0000 (disabled)
Meters
50 cc Sequential
B)
Off
1 gun
1 color
1.53 m / 5.01 ft.
0.25 inches
English
mm/dd/yy
Set at factory
Set at factory
0000 (disabled)
0 minutes
Feet/inches
Gallons US
1:1
5 percent
60 minutes
60 seconds
0
0
0
0 days
0.119 cc/pulse
0 cc
3A0869C