Technical Data - Graco ProMix 2KE Operation

Meter-based plural component proportioner
Hide thumbs Also See for ProMix 2KE:
Table of Contents

Advertisement

Technical Data

Maximum working fluid pressure . . . . . . . . . . . . . . . . . .
Maximum working air pressure . . . . . . . . . . . . . . . . . . .
Air supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air filter inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air filtration for air logic (Graco-supplied). . . . . . . . . . . .'
Air filtration for atomizing air (user-supplied)
Mixing ratio range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
On-ratio accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluids handled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid inlet sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid outlet size (static mixer) . . . . . . . . . . . . . . . . . . . .
Fluid flow rate range
G3000, G250 Meter . . . . . . . . . . . . . . . . . . . . . . . . .
G3000HR, G250HR Meter . . . . . . . . . . . . . . . . . . . .
Coriolis Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
S3000 Solvent Meter (accessory) . . . . . . . . . . . . . . .
External Power Supply Requirements . . . . . . . . . . . . . .
Operating temperature range . . . . . . . . . . . . . . . . . . . .
Approximate Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental Conditions Rating . . . . . . . . . . . . . . . . . . indoor use, pollution degree (2), installation category II
Noise Level
Sound pressure level. . . . . . . . . . . . . . . . . . . . . . . . .
Sound power level . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303, 304 SST, Tungsten carbide (with nickel binder),
3A0869C
See Models, page 3.
100 psi (0.7 MPa, 7 bar)
75-100 psi (0.5-0.7 MPa, 5.2-7 bar)
3/8 npt(f)
5 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
0.1:1 to 30.0:1
up to ±1%, user selectable
one or two component:
• solvent and waterborne paints
• polyurethanes
• epoxies
• acid catalyzed varnishes
1/4 npt(f)
1/4 npt(f)
75 - 3800 cc/min. (0.02-1.00 gal./min.)
38 - 1900 cc/min. (0.01-0.50 gal./min.)
20 - 3800 cc/min. (0.005-1.00 gal./min.)
38 - 1900 cc/min. (0.01-0.50 gal./min.)
85-250 Vac, 50/60 Hz, 2 amps maximum draw
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
41-122° F (5-50° C)
200 lb (91 kg)
below 70 dBA
below 85 dBA
perfluoroelastomer; PTFE
Technical Data