Control Menu

Set DMX Options

SET DMX MODE
From the Front Panel, this menu item allows the user to check (and if necessary change) the RDM mode.
BASIC
MONITOR
CONTROL
TEMP
SERVICE
Important: Please ensure that the DEC3.3 is NOT left in Service Mode.
SET DMX ADDRESS (in Monitor, Control or Service modes)
Select a DMX starting address in the range 001 to 510
1 – Lamp Relay
In Service Mode an addition two slots are available
2 – Fan Duty Control
3 – Heater Duty Control
Note that the DMX control is designed using a SAFETY pile-on Logic. So the DMX input can only override automatic
settings within safe limits.
SET DMX CURVE
DMX Curves affect the way the fixture relay is controlled in Control Mode.
DMX levels are shown as %.
Response Curve 1 (default)
DMX level 0-25 Relay disabled (open)
DMX level 26-75 No change to relay status
DMX level 76-100 Relay enabled (normally closed)
Response Curve 2
DMX level 0-19 No change to relay status
DMX level 20-40 Relay disabled (open)
Tornado G4 User Manual
Standalone operation, no DMX/RDM (factory default)
Standalone, plus support for RDM remote configuration and monitoring
Monitor, plus use of a single DMX slot to control Lamp relay
Same as Basic, but supports remote monitoring over RS485 with Ethernet adapter and Tempest
TEMP protocol
Monitor, plus use of three DMX slots to control Lamp, Heater and Fan
30