Control Interface

LED Indicators
Heater
ON (Green)
Fan
ON (Green)
Lamp On
ON (Green)
OFF
Lamp Relay
ON (Green)
ON (Red)
Temp
FLASHING
(Green)
ON (Green)
ON (Amber)
ON (Red)
FLASHING (Red)
Data
OFF
ON (GREEN)
ON (RED)
Tornado G4 User Manual
Heater is ON, to maintain lower temperature level or to prevent
condensation
Lamp is ON, or Temperature is HIGH and
Fan is cooling enclosure. Short burst when lamp off indicates fan moving air
to stabilize temp/humidity
Current sensing shows lamp is ON
Lamp hour counter is running
Current sensing shows lamp is OFF
Lamp hour counter is not running
Lamp relay is closed (normal)
Luminaire power receptacle is energized
Lamp relay is open due to over-temperature event. Luminaire power
receptacle is isolated.
Temperature is below lower temp setting
Temperature is in normal range
Humidity is above target limit
Temperature is above top setting
Temperature is above Trip level
Luminaire power is isolated
DEC4 is in BASIC Mode – Data not used. OR DEC4 is in TEMP, Monitor or
Control Mode and no valid data packet has been detected.
Good data packet received.
Control Mode: Data Fail. A previously good data signal has failed.
Monitor Mode: No RDM information being received (this is normal)
28