Wiring Access – Globe-down and
Horizontal Models
Locate the two Conduit entry holes on the enclosure rain
guard:
Conduit openings accept PG21 (International) and ¾" NPT
(North America) conduit fittings.
USE LIQUID-TIGHT CONDUIT FITTINGS OR CABLE GLANDS.
Use permanent or flexible, outdoor rated conduit to
connect power and signal cables to your Tornado
enclosure.
Use the plastic sleeves supplied to protect cables
between the conduit fittings and the internal wiring
terminals.
ALWAYS RUN POWER AND SIGNAL CABLES IN SEPARATE
CONDUITS.
Remove the DEC4 Controller cover.
Tornado G4 User Manual
Conduit Entry:
Conduit Entry:
SIGNAL
AC POWER
Flexible Conduit
with watertight
fittings
Plastic Sleeve
Cover
Thumbscrews
DEC4 Cover
14