For single feed wiring, no modification to the DEC4
Controller motherboard is needed.
Single Feed Power Termination
Connect Earth/Ground wire to Ground Terminal
Connect Live and Neutral to the terminals marked
FEED
AC Supply Voltage
Tempest Tornado enclosures require supply voltage in
the nominal range 200-250VAC, 50/60Hz.
North American installations – use a 208V
supply (2 x 120V hots), and connect one hot to
Line and one to Neutral terminals.
North American 120V versions are available to
special order.
Tornado G4 User Manual
IMPORTANT:
For split feed wiring, use a side cutter to cut both AC links at both
ends:
Split Feed Power Termination
STOP! Did you cut the power links? See above.
Connect Earth/Ground wire to Ground Terminal
Connect Enclosure feed to the terminals marked FEED
Connect Luminaire feed to the terminals marked SPLIT
SEE WIRING DIAGRAMS BELOW
16