Dec4 Main Functions; Factory Settings - Basic Mode - Tempest Tornado Marine G4 User Manual

Table of Contents

Advertisement

DEC4 Main Functions

1.
Sense current to luminaire (lamp on/off)
2.
Record lamp hours
3.
Monitor temperature and humidity inside
Enclosure
4.
Monitor temperature outside enclosure
5.
Maintain internal temperature at safe operating
level
6.
Maintain relative humidity within safe limits to
prevent condensation
7.
Isolate luminaire in case of unsafe temperature
8.
Report status over RS485, RDM, TCP/IP
9.
Maintain positive pressure (optional) 24/7 to
prevent ingress of salt air and other
contaminants
10. Circulates air internally to prevent hot and cold
spots when luminaire is idle
DEC3.3 constantly monitors the following parameters:
Luminaire/Luminaire current
Line Voltage
Temperature
Humidity
Factory Settings – Basic Mode
In most applications, DEC3.3 will operate correctly with its
factory default settings, in Basic operating mode.
You do not need to do anything. Please skip to the Power
Connections section below.
Standard default temperature and humidity settings
DMX, RDM and Remote Monitoring disabled
Best for standalone operation
Supports TEMP remote monitoring – see appendix
If your needs are more complex, read on.
Tornado G4 User Manual
DEC 3.3's patented Goldilocks
of sensors, heaters and fans to maintain a safe operating
temperature and a safe relative humidity level that will not
allow condensation to take place.
As air is heated it is able to support more moisture without
condensing, so Goldilocks uses heat to raise the air temperature
inside the enclosure in the event that relative humidity
approaches dewpoint.
TM
algorithm uses a combination
25

Advertisement

Table of Contents
loading

Table of Contents