8-26
8.7.8

Troubleshooting Leak Areas

Before repairing any leak, first read all of the steps within the applicable section. This will help to
eliminate unnecessary disassembly and reassembly of a radio with multiple leaks.
NOTE: All disassembly and reassembly methods can be found in
8.7.8.1 Seal Interfaces
• If leak occurs at one or more of the seal interfaces, disassemble the component(s) and inspect
the interfaces to determine if there is any damage. If no damage is observed,
re-assemble the radio as directed.
• If damage has occurred, replacement parts will be needed.

8.7.8.2 Battery Contact Seal

• If leak occurs due to damage to the Battery Contact Seal (43), it will need to be replaced.
8.7.8.3 Front Housing
• If leak occurs through anywhere on the Front Housing, replace the Front Kit Assembly (A).
8.7.8.4 Chassis
• If leak occurs through the Main O-Ring (28†††*), it will need to be replaced.
• If leak occurs elsewhere on the Chassis (33†††), it will need to be replaced.
Disassembly/Reassembly Procedures: Ensuring Radio Submergibility
Section 8.4.