Cleaning and maintenance
50/62
–
Screw the lid with the hose onto the new canister.
–
Push the hose well down so that it touches the bottom of the canister.
–
Put the canister back in the device.
–
Attach the seat.
Venting
NOTE:
Ventilate after changing the canister by switching over to
preset mode and then select Function 231 (see
'Voreinstellungen/Presettings', order no. 1011777-..).
–
Press the START/STOP button and the face fan plus button simultane-
ously.
–
Close the canopy.
The system will now be ventilated for 1 minute. AQUA FRESH will be re-
leased from the nozzles during this period.
–
Test the AQUA FRESH function afterwards. Repeat the ventilation proc-
ess if it does not work.