Gallagher T11 Installation Note

Gallagher T11 Installation Note

Hide thumbs Also See for T11:

Advertisement

Installation Note
Gallagher T11 Reader
This equipment contains components that can be damaged by electrostatic
discharge. Ensure both you and the equipment are earthed before beginning
any servicing.
The Gallagher T11 Reader
The Gallagher T11 Reader is a smart card proximity reader. It can be installed as
either an entry reader or exit reader. It can be mounted on any standard electrical
flush (gang) box, used in New Zealand, Australia, USA and Canada.
The reader can read Mifare DESFire EV1, Mifare Plus and Mifare Classic cards. The
Multi Tech variant can also read 125Khz cards.
The reader sends information to the Cardax FT Controller and acts upon information
sent from the Cardax FT Controller. The reader itself does not make any access
decisions.
The Gallagher T11 Reader uses the "Cardax IV Reader" communications protocol
to communicate with the Cardax FT Controller.
Installation Note | Gallagher T11 Reader
Part Number: 3E2513 R1 | 1

Advertisement

Table of Contents
loading

Summary of Contents for Gallagher T11

  • Page 1 The Gallagher T11 Reader The Gallagher T11 Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on any standard electrical flush (gang) box, used in New Zealand, Australia, USA and Canada.
  • Page 2: Before You Begin

    4 x self tapping, pan head, pozi fixing screws Power Supply The Gallagher T11 Reader is designed to operate over a supply voltage range of 9 - 16Vdc measured at the reader terminals. The operating current draw is dependant on the supply voltage at the reader. For the Standard variant at 12Vdc the current draw is 54mA (standby).
  • Page 3: Installation

    200mm (8 inches) away. Installation The Gallagher T11 Reader is designed to be mounted on vertically orientated electrical flush (gang) boxes, or any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range.
  • Page 4 Installation Note | Gallagher T11 Reader Secure the base to the flush box using the two 6-32 UNC screws provided. It is important the base of the reader is flush with and tight against the mounting surface. If you are not mounting to a flush box, secure the base to the mounting surface using the four fixing screws provided.
  • Page 5 Fit screw to secure facia to base Removal of the facia assembly is a simple reversal of these steps. Connections A Gallagher T11 Reader can connect to one of the following devices using the “Cardax IV Reader” communications protocol: •...
  • Page 6 Installation Note | Gallagher T11 Reader Connecting to the Cardax FT Reader Module (for the Controller 6000) Connect the wires to the sockets as shown: Positive Negative Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White CDXIV RX Blue...
  • Page 7 Installation Note | Gallagher T11 Reader Connecting to the Cardax FT Controller 3000-4R or 3000-8R The ports to which the Gallagher T11 Reader can connect are set up as groups, as follows: • Two groups (numbered 1 and 2) on the Controller 3000-4R, and •...
  • Page 8 Installation Note | Gallagher T11 Reader Make the connections from the Gallagher T11 Reader to either the Cardax FT Controller 3000-4R or 3000-8R as shown: Cardax FT Controller 3000-4R or 3000-8R Group PB1 and PA1... to... PB2 and PA2 (3000-4R)
  • Page 9: Technical Specifications

    Installation Note | Gallagher T11 Reader Technical Specifications Technical Specifications Routine maintenance: Not applicable for this reader Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth Power required: Voltage: 9Vdc - 16Vdc Current (at 12Vdc): 54mA (standby) Standard variant...
  • Page 10 • Consult the dealer or an experienced radio/TV technician for help. Note: Changes or modifications not expressly approved by Gallagher Group Limited could void the user’s authority to operate this equipment. 10 | Part Number: 3E2513 R1...
  • Page 11: Drill Template

    Drill Template 13mm (1/2 inch) diameter hole for cable 22.5mm (0.89 inches) 40mm (1.57 inches) 70mm (2.76 inches)