JOYSTICK TILT
Settings (Bold:
Description
default value)
STANDARD
Inclining the joystick forward tilts the
camera up. Inclining rearward tilts the
camera down.
REVERSE
Inclining the joystick forward tilts the
camera down. Inclining rearward tilts
the camera up.
ZOOM LEVER
Settings (Bold:
Description
default value)
STANDARD
Moving the ZOOM lever to the W side
(Wide) zooms out, and moving to the T
side (Tele) zooms in.
REVERSE
Moving the ZOOM lever to the W side
(Wide) zooms in, and moving to the T
side (Tele) zooms out.
FOCUS DIAL
Settings (Bold:
Description
default value)
STANDARD
Turning the FOCUS knob clockwise
moves the focus in the Far direction,
and turning counterclockwise moves
the focus in the Near direction.
REVERSE
Turning the FOCUS knob clockwise
moves the focus in the Near direction,
and turning counterclockwise moves
the focus in the Far direction.

GPI I/O

Sets the GPI I/O connector signal format and tally
operation mode.
SETTING
Settings (Bold:
Description
default value)
INPUT
Sets the control signal direction of the
GPI I/O connector to INPUT. In this
case, connect a tally control input
signal to the connector.
OUTPUT
Sets the control signal direction of the
GPI I/O connector to OUTPUT. In this
case, the connector functions as a
contact output connector which
outputs the camera number of the
target camera.
TALLY MODE
This setting is enabled when SETTING is set to INPUT.
Settings (Bold:
Description
default value)
NORMAL
Displays the tally input lamp
corresponding to the number of the
camera with tally input ON, and
automatically selects the camera as the
target camera.
ON AIR
Displays the tally input lamp
corresponding to the number of the
camera with tally input ON.
COMMAND SEL
Settings (Bold:
Description
default value)
STANDARD
Sets the input/output method to
STANDARD method. The camera
numbers and input/output pin numbers
have a 1:1 correspondence.
• If the unit and cameras are
• If the unit and cameras are
EXPAND
Handles camera numbers as binary
numbers.
• Tally input numbers 8 and higher in
• Numbers in a LAN connection,
CAMERA LINK
Settings (Bold:
Description
default value)
ON, OFF
Turns tally lamp control on/off. The
tally lamp control operation varies
depending on the combination of the
SETTING and CAMERA LINK
settings. For details, see "Tally lamp
control operation" below.
Tally lamp control operation
Tally input lamps
Tally lamp
47
connected by serial connection,
cameras 1 to 7 correspond to input/
outputs 1 to 7.
connected by LAN connection,
cameras 1 to 10 in group 1
correspond to input/outputs 1 to 10.
a serial connection are ignored. In
this case, the response is equivalent
to no input.
corresponding to cameras 1 to 10 in
groups 1 to 10, are handled as the
numbers 1 to 100. Tally input
numbers 101 and higher are
ignored. In this case, the response is
equivalent to no input.