IP control card is set to 192.168.0.100 by factory
default.
• Connecting stackable switching hubs in up to 2-
tier configuration is recommended to avoid
network delay.
Notes
• Do not connect more than 100 cameras, five
remote controllers, and one setup PC across all
networks, even if controlling a camera that is on
a network of a different segment via a router. If
you connect more devices than this, problems
may occur, such as control delays or cameras are
operated incorrectly due to IP address
duplication.
• If you perform the setup from multiple PCs, the
settings may not be made correctly. Perform the
setup from one PC.
• Set the setup PC so that only the network that you
use is enabled.
• Do not connect cameras and remote controllers to
a public network.
3
Connect the cameras and remote controllers to AC
outlets using AC adapters and AC power cords.
The cameras pan/tilt automatically when power is
turned on.
Assigning cameras
Link the camera numbers, used for operating cameras
from the unit, with the cameras on the network. This is
called camera assignment.
A list of the assigned cameras is saved in the unit as a
camera table.
Camera numbers are sequential in each group, and are
selected using the GROUP buttons and CAMERA
number buttons of the camera selection block.
Camera assignments are performed using AUTO IP
SETUP >SETUP IP or AUTO IP SETUP >ASSIGN
CAM in the RM menu.
Note
Only cameras that are on the same segment as the
remote controller can be assigned using AUTO IP
SETUP.
Use the setup software to assign cameras on different
segments.